<s>[INST] FTView SE faceplates for PowerFlex525 and for CIP motion servo drives Summary: FTView SE faceplates for PowerFlex525 and for CIP motion servo drives Does anybody have these templates? [/INST] Download the latest DMAT (Drive and Motion Acceleration Toolkit). After downloading it you must run the Current Updater to update. Both the AOI and faceplates will be found inside the DMAT. See also the following technote for infos: 519334 - Drives and Motion Accelerator Toolkit(DMAT): Download and Support - fuzzy logic In order to enhance the reputation of the Forum's contributors, please rate the replies you got and remember to close the thread clicking Choose as Best Answer button over the solving answer. Thanks ! Thanks for the reply. I have done that already. The DMAT faceplates are for FTView ME. I found out that faceplate for PowerFlex 525 will be available second week of March from Rockwell. No plans for CIP motion drives though. n </s>
<s>[INST] FTVIEW SE WITH SIEMENS S5 CAN I EMPLOY THE HMI FTVIEW SE TO PULL INFORMATION FROM SIEMENS S5 155F CPU942?HOW SHOULD I IMPLEMENT AND CAN I GET FEW APPLICATION NOTES? [/INST] You can install 3rd party OPC server for SIEMENS S5 155F CPU942 and let FTView SE pull the data from the 3rd party OPC server. KEPServer Enterprise provides serial and Ethernet OPC servers that allow communication between many third-party industrial devices and RSView32, FactoryTalk View Site Edition, and FactoryTalk View Machine Edition. All drivers are supported by Rockwell Software. You may order it using the following catalog # : 9301-OPCSRVENE See this LINK to understand how it works and to download driver manual... this is the KepserverEX product, sold by Kepware, but the driver is the same you may find inside Kepware Enterprise sold by Rockwell Automation as indicated above. Hope this helps, - fuzzy logic n </s>
<s>[INST] Wheel-Scrolling the tag list Summary: Who's having difficulties scrolling through the tag list of RSLogix5000 using a scroll wheel of a mouse?I've been through the Knowledgebase. It says update the mouse driver. It's a lame excuse. Why? Because nothing else in the computer, not one single other program, has difficulties with the scroll wheel. Even in the same program, I can scroll through a ladder diagram with it. It's ONLY the tag lists. That's not a mouse driver problem. That's a Rockwell Software RSLogix5000 problem. Are there others with similar problems in RSLogix5000 tag lists with scroll wheels? TJ McDermott [/INST] What version of 5000 are you using? I'm having no issues using the scroll wheel. I have come across this as well. It usually works for a while and then stops, a reboot usually restores functionality. The Scroll Bar is the Least of my worries! I've encountered the problem with 17 and 19. Haven't used 18 with it. Rebooting does not fix the problem. The mouse driver is Intellimouse, and it's pretty darn recent. I reiterate that it is not a mouse driver problem when no other program has this behavior. Had the same issue. I installed an old app (now freeware) called Flywheel from Plannet Crafters. Fixed it for me. That does in fact fix the problem. But WHY? Why does Logix5000 TAG BROWSER ONLY require this? The ladder diagram does not. JUST the tag browser. Not ONE other program does this. Works okay on my computer in 19 & 17. n </s>
<s>[INST] direct ethernet connection Summary: How do I connect a Micro850 directly to the ethernet port of a Win 10 PCI have been struggling with establishing a connection between a Micro850 and my Win 10 PC. When the PLC and the PC have DHCP configured ports, the autoconfiguration from the PC to the PLC provides an address that is unreachable. RSLinx cannot find/establish a connection when I set static IP addresses for both. This video (https://www.youtube.com/watch?v=BU7O8KXfdPA) got me partially on the way, but alas, there is no joy in PLCville. I am frustrated and stumped. Is there a documented procedure for how to set this up? Thanks. P [/INST] If the Micro850 is set to DHCP, you need a DHCP server to hand out addresses. Rockwell's BOOTP can act as a DHCP server if your Micro850 is set to DHCP. Run BootP and configure it. You should then see the MAC address of the PLC. You can then use BootP to assign an address to it. I'm assuming you used the USB port to assign a static IP address? Did you set your computer to the same subnet? (stupid questions, but others have not so the question has to be asked). Did you check the box for static so the address sticks? If you've assigned an address via USB, have you power-cycled the processor? Does the address stay set when you look at it via Linx? Do you have your Linx Ethernet/IP driver pointing to the correct adapter? The video you linked makes a lot of assumptions. First, that the address is already set in the processor. I'm pretty sure a new processor out of the box is set to DHCP. If the Micro850 or your PC is set DHCP and does not see a DHCP server, they will default to an IP address within the APIPA scheme (169.254.0.1 to 169.254.255.254 with a subnet mask of 255.255.0.0). What are your current IP addresses and subnet mask for both your PC and the Micro850? Since you said they are directly connected I am going to assume there is nothing else to worry about on the network. Can you see the Micro850 in Linx over USB? If so, you can verify the current IP settings within Linx by right clicking on the Micro850 and selecting Module Configuration, then clicking Port Configuration. You can verify your PC IP address using the video you linked as a guide. Remember, subnet masks between your PC and the Micro850 must match and the IP addresses must be in the same range (eg. if subnet mask is 255.255.255.0 then the first three octets of the IP addresses must match, such as 192.168.1.x). Once both are configured correctly, you can verify connection by opening the cmd prompt and typing ping [Micro850 ip address]. If the ping replies, then it is likely an issue within Linx. RSLinx has some common issues, but one that I see a lot is Wi-Fi messing with comms. After you verify that you are looking at the correct ethernet adapter within your Ethernet/IP driver settings try to disable your wireless adapter. Sometimes RSLinx can get confused. Also, make sure you are using the EtherNet/IP driver, not the standard Ethernet driver. TJ and Jeremy: Thank you for your replies. I have been very diligent about the subnet...I am familiar with the issues if the subnets don't align. I have setup a second ethernet port on my machine using a usb-ethernet adapter. Furthermore, I have configured that adapter/ethernet port to have a static IP address of 192.168.1.2. I have also disconnected the PC from the network as well disabled the wi-fi. When I run BOOTP, it does not detect the Micro850: the discovery history pane is empty. I created a relation manually using the PLC's MAC address and assigning it an address of 192.168.1.3, then restarted the PLC. When I click on Enable DHCP, I get failure to connect (time out) message. For some reason, the PC cannot see the PLC. I'm stumped. Your thoughts? Thanks again. Patrick In almost every case, this means the PLC already has an address and it is not on the subnet you think it is. Get a USB A - B cable (commonly used for printers) and connect to the PLC that way. It's the fallback for exactly the situation you find yourself. Plug cable into PLC and into your computer. Open RS Linx and you should see the USB connection appear. Right-click on the processor and select MODULE CONFIGURATION. Fix the IP address settings via USB and you should be good to go. Worst case, you have to then cycle power to the PLC. Actually, worst case is the one time this doesn't work and the PLC is actually toast. But I don't think that's your problem. n </s>
<s>[INST] MotionView Software Hello, I am needing to try to go online with a Kinetix 300 servo drive and I cannot locate the software to save my life. Anyone know if there is somewhere I can download the software? And is this a software that I need to purchase? [/INST] I believe MotionView is an onboard java application in the drive, isn't it? If you type the IP address of the drive into a browser it should give you the option of running or saving the java application and creates a MotionView.jnlp file (Java Network Launching Protocol). You would, of course, have to have a compatible version of java installed. Compatible version depends on firmware of the drive, I think. EDIT: Hey, I found a QS! https://literature.rockwellautomation.com/idc/groups/literature/documents/qs/cc-qs018_-en-p.pdf Regards, RM n </s>
<s>[INST] IMC block, sample time too small? Summary: What causes the error sample time too small?I have an IMC block with an error sample time too small anytime the deadtime in the model is greater than 0. Any ideas? [/INST] You must configure other parameters accordingly ... this is a complex instruction and should be treated in its entirety... - fuzzy logic In order to enhance the reputation of the Forum's contributors, please rate the replies you got and remember to close the thread clicking Choose as Best Answer button over the solving answer. Thanks ! n </s>
<s>[INST] 1791D-8B8P modules to test Hi Everyone, I'm interested in know how to test 1791D-8B8P modules without a PLC running, some techniccian have change all modules in a system but I cannot believe this modules are bad, how can I test it with a Computer with RS links and RS logix? thanks [/INST] Hmmm... you will need a Devicenet Scanner to check if the module operates correctly... RSLinx is needed to go online with a *valid* Devicenet network (and with your module), RSLogix is only needed to program a PLC and see if data come and go to the modules... but through a scanner :smileysurprised: RSnetworx for Devicenet is also needed to configure your network... :smileysurprised: - fuzzy logic n </s>
<s>[INST] versaview 1200w I use an industrial computer versaview 1200w running TT2000 software as HMI with Allen Bradley PLC5/40C.When i come back from screen saver and i push F1 or other, the screen will be black with the message: parity check.To resolve the problem i should restart the computer each time! ! [/INST] Parity errors sound hardware-related. I'd call Tech Support to confirm you don't have a bad unit. n </s>
<s>[INST] RSLogix 5000 Version 20.05 Installation issue During installation of any Rockwell Software package it fails reporting an error: Error 1335. The cabinet file 'Data1.cab' required for this installation is corrupt and cannot be used. This could indicate a network error, an error reading from the CD-ROM, or a problem with this package. How can I solve this problem? [/INST] Hi @Tinta Gutierrez, Welcome to Engage! ​I've just searched the Knowledgebase for this error; there are many different references, but the one most related to your issue is the following: BF19477 Hi Tina - I have had the same error message with at least one minor version number of Version 20.0x. I apologize I don't recall specifically if it was 20.03, 20.04, or 20.05. Fresh re-downloads from the Rockwell site of the version was no help. As Akhilesh mentions, my problems were when I was installing on a VM. The solution for me was to just move to the next higher minor revision number. i.e. 20.10.00 or similar​ n </s>
<s>[INST] Redundancy in 1769-L30ER CompactLogix5330ER Summary: How much synchronization is there?This is a question about the limited redundancy in the new 1769-L30ER CompactLogix5330ER controller. This is not about the bumpless failover redundancy in full ControlLogix systems. My questions pertain to what is synchronized and what is not. Q. What happens to a tag value changed in an HMI? Suppose a setpoint assigned to a DINT tag is changed in a PanelView. Then a few moments later the processor fails and the other processor takes over. Does that new processor have the recently changed setpoint tag value? Q. What happens to internal tag parameters that are not really accessible from logic, such as the accumulated integral term of a PID loop? Q. Does the program scan get synchronized at all? [/INST] Is Rockwell Automation advertising a limited redundancy for those controllers, or are you talking about CompactLogix Backup with DeviceNet ? I haven't seen anything new for the L30ER. The answer for each of your questions is yes for ControlLogix Redundancy and no for CompactLogix Backup with DeviceNet. Only the DeviceNet scanner data tables are synchronized in the CompactLogix Backup system. Edits, data table changes, and tag value synchronization would have to be entirely implemented in user logic and procedures for the CompactLogix. How are tag database changes updated in the standby controller? The two DeviceNet scanners are updating their Input data tables at the same time, but everything else is independent. The tag database in the active controller is not automatically updated in the standby controller. You need to use Produced Tags or MSG instructions to update changes made to the active controller's tag database. It's a lot of complexity and frankly a lot of work. That's why the ControlLogix Redundancy system, which does all of these features automatically, is more complex, more powerful, and more expensive. n </s>
<s>[INST] ACD File Viewer? Summary: Does there exist a free or less expensive program that can view ACD files, or is it at least possible to export from the original into a more generic filetype which could be freely viewed?All, My company was sent an ACD file created with *RSLogix 5000. I'm trying to figure out if we can avoid purchasing the full version of *RSLogix 5000 since we only need to view the file, not edit or create these types of files. Does there exist a free or less expensive program that can view ACD files? If not, is it at least possible to have the author of such files export from the original into a more generic filetype which could be freely viewed? Thanks, Chris [/INST] the author could send you a pdf file of the program. i think it is called Generate report ... There is a service edition that is much less expensive which allows you to view, upload / download, and change tag values. There is also a CompactLogix-only version. n </s>
<s>[INST] Kinetix 5100, disconnect encoder without fault Hello, I would like to know if it is possible, by ethernet ip, to disable the kinetix 5100 drive, it is to be able to disconnect the encoder (through an ATI tool changer), so that, while it is energized, to be able to make the change, and it does not cause an non-recoverable fault, since the way I know to reset the non-recoverable fault is to power cycle or reset the module, and it takes a long time. Another question, if the tool changer is used constantly, while the drive is energized, can it cause damage? Thanks a lot. [/INST] Alejandro I cannot find any documentation to suggest the encoder is RIUP (Removeable or Insertion while Under Power). This can be interpreted as the encoder connection was not designed/tested nor supported for RIUP. If the Kinetix is power but the CIP axis is disabled (open loop), I believe it is still reading the encoder position and it would register an encoder fault. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090640 data-linkindex=0>Kinetix 5100 Servo Drive E011 Encoder Error Troubleshooting Thanks Philip: We have been able to clear the fault after reconnecting the servo motor, the question now is, will we damage the drive or servo motor if we keep disconnecting it while it is powered up? n </s>
<s>[INST] 1719 Ex Digital Input Line Fault Detection (LFD) Can I use mechanical contacts without Line Fault Detection (LFD) or will that void the hazardous listing? Resistors R1 & R2 are shown in the blue hazardous area/device, Is that a requirement or can this be done at the 1719 module? Below is copied from Rockwell Automation Publication 1719-IN001D-EN-E - November 2020 Line Fault Detection Most I/O modules have a line fault detection function that can recognize a lead breakage or a short circuit. • 1719-IBN8B or 1719-IBN8 digital input module If the input is used, for example, with a mechanical contact, an additional resistor circuit must be installed to ensure that the line fault detection function can work correctly. Using the additional resistor circuit, the electronics can distinguish between a closed switch and a short circuit. Thanks [/INST] Hello KR721, I'm not too familiar with intrinsically safe I/O, but I discussed your question with a co-worker who has much more experience than I do. Unfortunately you do need the line fault detection for the hazardous rating. Installing the resistors at the 1719 module instead of the end device would make it possible to have a fault on your cabling that is not detected, therefore you do need to install the resistors closer to the end device to have better fault detection. Best Regards, David Geck I did find a link on how to disable Open-Wire Detect. I understand the knowledge base is not intended for design advice, I think there should be an asterisk/note informing you that hazardous rating could be affected if this feature is disabled. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1076466 Thank you for clarifying the resistor location. n </s>
<s>[INST] PV C600 Component and Tag Data base from RSLogix 500 Is there a method to import the data base from my RSLOGIX 500 program into the PVC600 Paneview Explorer? [/INST] ... Adder to this question. I'm in the tag/database section of the web based developer and is it possible to have the database add new entries via a paste or do I need to create a bunch of tags then paste into the added items? Although the ability to import/export tags directly from a file is not currently supported in the product, you can copy and paste tag information to/from editors such as Excel, which greatly simplifies tag configuration operations. See Aid 51940... you may export tags from RSlogix 500 using the ASCII export to a .csv file, then import in the PanelView Component editor. - fuzzy logic n </s>
<s>[INST] Factorytalk SE VBA Hi, I wanted to find out if there is a way to change the tag address of Logix 5000(direct tag) through vba script. In rsview 32, it can be done in vba by tag.address and tag.WriteConfiguration, but i need to know how to do this in Factorytalk SE. There must be some vba code to change the tags address in runtime using vba code. Please reply if anyone knows. [/INST] Sorry, the SE object model is vastly different than RSView32. No way to change a tag address using VBA. Wish I had better news. n </s>
<s>[INST] Data arrays and FT Historian Summary: How can I read data arrays in FT Historian 6.00.00 ?Hi all, I am trying to find a way to read data arrays with the FactoryTalk Live Data InterfaceNode but I did not manage to success. Could you please guys advise any hints on how to configure the PointBuilder settings in order to be able to successfully achieve my goal? I am using the FT Historian SE 6.00.00 version. Thank you [/INST] nan n </s>
<s>[INST] Rehost Activations from a broken dongle Summary: My USB dongle was broken on a job site. I want to rehost the activations directly to the laptop. The USB dongle does not work as it was physically damaged. I want to rehost the activations directly to the laptop, but I am unable to find them. Using FTA Manager I can only get to the FTA System Placeholder. How can I rehost these activations? [/INST] Welcome to the Forum ! You need to call in Tech Support for your Region, as they can help you to rehost your activation also if the dongle isn't working. - fuzzy logic In order to enhance the reputation of the Forum's contributors, please rate the replies you got and remember to close the thread clicking Choose as Best Answer button over the solving answer. Thanks ! n </s>
<s>[INST] Activation I have a activation in my Hmi server for Ft View SE 100 and I have the window that pops up running in grace period. The activation is in the Rockwell/software/common/activations Directory, and also in the Activation tools under settings it is pointing there, And start is highlighted. Any direction on how to solve this would be greatly appreciated. What happened to the good old days with the floppy disk activation. Thanks. [/INST] First check if your activation is present in FactoryTalk Activation Tool under Rehost tab...that means it is correctly allocated in the right folder and the file .lic is correct.Then you need to check if it is also present in the Current Activation tab... if not, go in the last tab of the tool and press Start, to run the Activation server...it should remain started...Open again the Current Activation tab, and you have to see your activation, so that the software can run normally.Also take a look to the following technotes: Aid 50260 - Aid 52838 - Aid 35092 Hope this helps… - fuzzy logic Thank you. New activation webpage unworkable. I can't enter the dongle number to get an activation and I can't browse because the servers with the dongle and software are not on the Internet LAN and will never be. This change in the web page functionality makes activation impossible for us unless I shutdown the plant, pull the dongle out of the server and put it on my computer along with the activation client. It's time to look into alternatives to Rockwell crap wherever possible. To enter the dongle number in the activation webpage, look at the FlexNet ID number printed in the dongle. In the HostID field, enter ONLY the 8 digits after ID-9. See the attached picture If you still have problems, please contact techsupport, they will be able to help you. n </s>
<s>[INST] CCW compatible with 1734-AENT Point IO Module Summary: Is CCW compatible with 1734-AENT Point IO ModuleDoes anyone know if CCW is compatible with 1734-AENT Point IO Module? We were setting one up in the shop yesterday and tried to connect with it. The software was able to Discover it, but wouldn't do anything else. [/INST] The 1734-AENT module is a distributed IO network adapter; you can't really DO anything with it by itself. It has to be part of a processor's program (at least in Logix5000 it does). You could examine the contents of the IO rack (see the IO modules attached to it) using Linx, or you could get some diagnostic information from it by putting the IP address of the 1734-AENT into a web browser. n </s>
<s>[INST] EM Brake option for the PF40 Greetings, I have a customer looking to have a brake motor (c/w Electro-Mechanical brake (EM brake)). The digital inputs on the drive have an option for the EM brake release, however that parameter option is not available on my demo. The firmware on my drive is at version 2 levels. In what firmware did that option become available? Can I flash the firmware up on the drive? I haven't been able to find a way to do this. Thank you,Chris [/INST] Hi Chris, unfortunately PowerFlex 4/40/40P/400 drives are not field flashable by enduser.Please contact Rockwell Automation Technical Support Centre for further information. Anyway the release of the firmware where this option in the Digital Input was added is 3.02...actually the shipping firmware on those drives is 6.01. Hope this helps… - fuzzy logic How about with the PF40P, what firmware was the EM brake release added to parameter 51, bit 27? Disregard, found info I needed. n </s>
<s>[INST] Micrlogix 1500 LRP Series C and expansion module 1769-IQ6OW4 with V8.10 [CPR9]. Are there any known issues where the processor randomly faults with error message module does not match the i/o configuration. [/INST] Is it the only expansion module? Is the Bus terminator properly installed (1769-ECR) ?Which is the exact error code do you get ? Sometimes this error comes due to hardware failure, or faulty connection between module and base .... Try to re-read I/O Config to verify the software populates the configuration with the correct I/O. There was a known problem in previous RSLogix versions (v7.x) where the Extra Data Lenght for that module was badly configured; just take a look it should be 5. - fuzzy logic n </s>
<s>[INST] FactoryTalk View ME 5.0 - Faceplates supported? I found the following in the 5.0 release notes for FactoryTalk View ME: Adding RSLogix 5000 process faceplates - FactoryTalk View Machine Edition now includes a number of global object-based process faceplate displays for RSLogix 5000 instructions that are commonly used in process applications. These faceplates can be added to an application automatically, either when the application is created, or later. Now, can I do this in a PV+ (not a PV+ CE) or is it still restricted because the OS of the PV+ doesn't support ActiveX? [/INST] Process faceplates are pre-configured graphic displays and global object displays that interact with Logix5000 processors. They can be used also on Panelview Plus. Anyway, there are some considerations to be aware using Faceplates with ViewME: take a look to Aid 47918 Hope this helps… - fuzzy logic As a reference, you may also find many other faceplates for PVP in the Sample Code Web page Take a look to the following screenshot.... :smileywink: - fuzzy logic Thanks for the posts. I found it in 5.0 and it looks like it will work great. One question - the naming had me a little confused. I kept seeing that Faceplates were supported in the PV+ but I also saw that Faceplates were not supported because they were ActiveX objects. Obviously what I found in 5.0 is not an ActiveX, it's just a Global Object that was created. The naming just threw me off because it seemed like it was being used for 2 different types of objects. Thanks again for the help! I know where the confusion is... :smileytongue: There are some technotes (i.e. 38688) referred to faceplates for RSLogix5000 that are Activex and thus cannot be used in a PanelviewPlus... they come inside RS5000 installation disc... they should not be confused with RS5000 PROCESS Faceplates that come with FactoryTalk View disc...and are based on Global Objects... That's all..... :smileywink: - fuzzy logic n </s>
<s>[INST] Write Text File Summary: Create and write to a text file on eventI a m looking for a way to create, append and write to a text file when an operator presses a button or on a specific event such as an indicator. Currently using RSView SE 4.0 but migrating to 6.0 in the next two months. [/INST] I can only think to a possibility using VBA, but I'm not an expert on that... I may suggest to take a look to the following technotes: Aid 22007 - using VBA to execute a command when an event occurs Aid 22705 - an example of VBA code to create a text file (the example is for RSView32, but I guess it could be useful anyway) - fuzzy logic Please remember to Rate the Comments( ) to enhance the reputation of the User who provided help,or close your Topic using the ( ) button over the answer that solved it. Thanks... n </s>
<s>[INST] Micrologix 1200, 1762-L40BWAR Hi all,Is there a way to increase memory in ML1200.I am worried that I might run out of space with my program.Any thoughts other than going with different PLC?Thanks. [/INST] Unfortunately it isn't possible... :smileysad: they have fixed size of memory.... - fuzzy logic n </s>
<s>[INST] E-Monitor Odyssey and Vista/Windows 7 We are going to be changing operating systems to Vista/Windows 7. Will my Emonitor Factory Ver. 3.40.22 Build 22 continue to work? If not what are the options? [/INST] Please refer to the following Topic: http://forums.rockwellautomation.com/t5/forums/forumtopicpage/board-id/ICM/message-id/22 Hope this helps… - fuzzy logic Thanks, I thought I had seen that post at one time. n </s>
<s>[INST] FTview Studio ver 8.10 open file problem Summary: FTview Studio 8.10 will not open demo projects or newly created projectsHello All, My View Studio software version 8.10 will not open demo projects or newly created projects; I can save it, but I can't re-open it from directory Users/Public/Public Documents/RSview Enterprise/ME/HMI Projects. Anyone has this problem ? . Please see attached. Thanks. [/INST] Check https://rockwellautomation.custhelp.com/app/answers/detail/a_id/623587/page/1 n </s>
<s>[INST] rslogix5 software installation error Hello... Any guys encounter same problem with us here. I have attachment result of installation of license of rslogix5. We encounter intermittent connetion of internet in the plant when doing such activity. Is it still posible to retry acquiring license for the second time? Please refer to the attach print screen result of our activity as reference. Best regards,DATA [/INST] Just try again to retrieve your activation then, if you cannot download it or you still encounter the same problem, please call in Technical Support and they will help you on that. - fuzzy logic n </s>
<s>[INST] totaliser The platform for rslogix using which dont have fbd because of it is mini programming package. i want to do the totaliser for toal;ta water fl;ow. i tried one logic for that i took sample for particular period and then add it to toaliser but i am quit confusing if flow rate is highthis may not work perfectly so there is any alternative method for this one. rahul [/INST] Try to take a look to the following thread : http://forums.rockwellautomation.com/rockwell/board/message?board.id=ProgrammableControllers&message.id=634&query.id=228876#M634 Maybe there is what you need... if you have problem to open the technotes indicated, send me a Private Message here in the Forum with your e-mail address...I may send you back some examples... Hope this helps… - fuzzy logic [email protected] n </s>
<s>[INST] Borrowed Activations but product still not activated Summary: Borrowed activations don't seem to be activating productI have several activations on my laptop borrowed from our Toolkit Activation Server including RSV.STUDIO and RSVME.STUDIO. Why do I keep getting Product not activated warnings listing RSV.STUDIO and RSVME.STUDIO? [/INST] Please add some other infos: FactoryTalk View Studio version FactoryTalk Activation tool used (old one or new Activation Manager ?) Also, some screenshots of the situation are welcome... - fuzzy logic Please remember to Rate the Comments( ) to enhance the reputation of the User who provided help,or close your Topic using the ( ) button over the answer that solved it. Thanks... Windows 7 Pro 32-bit FT View Studio 6.0 (CPR 9 SR3) FT Activation Client 3.02 (CPR 9 SR2) FTSP 2.30.01 (CPR 9 SR3) I checked the compatibility matrix and my version of the Activation client isn't supported with Win 7 or FTSP 2.3. So, I need to upgrade my Activation tool and that will probably fix it. I'll post an update after I get that done. Thanks! Tavo I upgraded to Activation Manager 3.30 (CPR9 SR3) and I still have the same issue. I thought maybe if I returned the borrowed activations and re-borrowed them it might help. I connected via VPN to our activation server and I was able to return them but now the activation manager doesn't show me any activations to borrow. I know they are there because I can open FTView Studio and it comes up fully licensed if I'm connected to the VPN. The screenshots below show the Windows message I get (top left). I have to click on View the message to see the Product Activation Failed message(top right). At the bottom is the list of borrowed activations from the old version of the Activation Client. I had the same activations in the new client before I returned all of the Studio related activations. The screen shot of the Product Activation Failed message was taken before I returned the Studio related activations. Any thoughts? Did I miss a required activaton for FT View Studo SE/ME? Tavo, I think you've unintentionally caused some issues having different CPRs on your PC, and guess now isn't enough to just install the Activation Manager (that is the same CPR and SR of other installed software) on your PC to solve... I'm also having many troubles at customer's sites when they just install come CPR 9 SR2 products and some CPR9 SR3 together. It seems to me this last combination is particularly dangerous. Saying that, I've not particular suggestions unless the complete repair or reinstall of those software... (FTSP, FTAM,FTView) Anyway, for your reference, try to take a look to the following technotes about borrowing intricacies... 58950 - Does a borrowed activation have any dependency on a Host ID ? 58612 - My Automation Toolkit Borrowed Activation does not work when I disconnect from the server computer, but it works when Im connected - fuzzy logic Please remember to Rate the Comments( ) to enhance the reputation of the User who provided help,or close your Topic using the ( ) button over the answer that solved it. Thanks... n </s>
<s>[INST] FT Activation report ? Summary: We have multiple developers and multiple deployment servers We have multiple developers and multiple deployment servers and we would like to have a mechanism by which we can generate report of how many activations are present of computers and how many of them are being used. I went through the activation manager tool and could not find any feature which can generate report of this ( Available Activations tab under activations manager ). Is there any way we can generate report of this data ( may be in excel or csv ) and export it so that our other products / departments can use it ? Thanks, Vijay Aundhekar [/INST] Sorry Mr. Aundhekar, there is no way to do what you wish to do using Rockwell's tools. One would think that a company which sells a product call Factory Talk ASSET Manager might understand the need, but at present, you're on your own. Try your local Rockwell provider or Rockwell tech support. I was able to get a spreadsheet of all of my company's software purchases. It included if they were activated and, what ID it was attached to (dongle ID, hard disk serial number, etc) n </s>
<s>[INST] RSView32 project to FactoryTalk View Hello to all, I am trying to open a backup file (.zip) of a RSView32 project (.RSV) that was made by a consultant for my company 3 years ago. I received a FactoryTalkView 30 days demo license from Rockwell by email. I am unable to open such backup because the manager is searching for a .apa file instead of a .zip file, like RSView32 use to. I do not know FactoryTalkView. Can somebody help me please? Thank you. [/INST] Hi quesnel1, and welcome to the Forum ! :smileyhappy: First, just to be sure, you'll need to use FactoryTalk View SE version to import your RSView32 project... then, you have to restore your backup to the machine where you want your project to be imported, using the RSView32 Transport Wizard... After that, you have to create a new View SE project, select Import and browse for the RSView32 project... View SE online help contains some tips about the import procedure...search for Import a project for an HMI server. Hope this helps… - fuzzy logic Fuzzy left off an important step - you need to unzip your backup first :smileywink: Once it is unzipped, the rest of the procedure should work. You open Studio (I am assuming SE Station, not a distributed application), go to New tab, give it a name and click Import. Next, select the .RSV file from the project (you need to change the File Type to RSView32). The rest should be a piece of cake. Oh yes, thanks... that would be useful if you've not the RSView32 Transport Wizard installed on that PC... otherwise, you may use the Transport Wizard to restore it, and it accepts the .zip backed up project file as source.. :smileywink: - fuzzy logic I think we might have mis-understood quesnel1's intent. He has an RSView32 project archive, and wants to open it. But instead of having RSView32 Works, he has FactoryTalk View Studio. We assumed that he wants to convert his RSView32 project to FactoryTalk View Studio. I think instead what has happened is that he got the wrong visualization development software. I'm just guessing. n </s>
<s>[INST] Studio 5000 Recovery File Summary: Compact Logix ControllersCan anyone give me some info or a link to info for Studio 5000 Recovery File. [/INST] i'm not sure what you are looking for. Studio5000 makes a .bak file which can be used as a recovery file n </s>
<s>[INST] solution for replace 1747-L542P Is there any solution for replace 1747-L542P? Please advise [/INST] Unfortunately there isn't a direct replacement... :smileysad: I guess you may realize this with *modern* controllers, but it should be completelyredesigned.... I've found a thread in another forum that is quite old, but has some infos... - fuzzy logic n </s>
<s>[INST] Locking displays untill abort command Hi I am trying to lock some of my popup displays in factorytalk view SE so that the user cannont exit the popups without pushing a confirm/ok button to exit. I do not want them to be able to change to other screens or push other buttons on displays in the background whilst this popup is displayed. Any idea how I do this? [/INST] There is no mechanism currently to support modal popups. Even if you used VBA and forced the selected popup to stay on top, there's no way to prevent the operator from clicking on stuff behind the popup. The only way to do what you want to do is to make your popup full-screen. It will force the operator to take notice and prevent him/her from clicking behind it. It also prevents the popup from getting lost behind the screens. Not so graceful, I know, but it gets the job done. n </s>
<s>[INST] convert the analog output to a time proportioning using Micrologix 1400 Summary: I need control the heater unit for temperature control. I have SSCR with digital Inputs. How Can I convert the analog output of the PID to a time proportioning on/off output. [/INST] There are 3 PWM built in. They can be accessed through the PWMX function files under Controller in the project tree. Be aware there are some restrictions with regard to outputs. Attached is a home made PWM. Rob Barrese n </s>
<s>[INST] lost usb dongle with activations We shipped a pc to another plant to use and the usb dongle did not make the trip. Is there a way of replacing it? [/INST] Replacing the dongle requires purchasing another one. As far as allowing them to use the software without the dongle. You can follow the rehost proceedure and host the license to another device. Thanks for the info. To be more specific, the dongle had the keys on it from another computer. SteveB, normally the usb dongle fuctions the way mentioned below. A Dongle is a USB hardware device that gives out an address (Host ID), that your activation is tied to. You can purchase it from your local distributor, the part # is 9509USBDONG. NOTE it is not a Memory stick, you can not save your activation file on a it. Your Activation file has to be saved on every computer that will use the software in the activation directory. i.e. C:Program FilesCommon FilesRockwellActivations. Your new software will activate when you attach the Dongle. So dont worry about the .lic file it is stored in your pc in the address C:Program FilesCommon FilesRockwellActivations. So you just need to purchasea new dongle.hope it helps.:smileywink: Informations from vikas clarify the Dongle use; this and other useful infos on FactoryTalk Activation could be find in the following technote: Aid 35251 Anyway you will need to Rehost your activations to the new Dongle; the following technote is specifically on that: Aid 44620 There is an exception on that procedure: if the activation file has been deleted, you cannot use the website to rehost. You must call Rockwell Technical Support. - fuzzy logic Thanks for the help! This is my first experience with a dongle. I am from the old school!!! n </s>
<s>[INST] How do I graphically fill a tank on a screen? What color goes into the tank, I would like it to be blue, is it the pattern color? [/INST] Hi William, is it a Rectangle object? The Fill animation uses the object's Back color. fuzzy logic Please don't forget to use the LIKE button and highlight the decisive answer : REPLY > Make Best Answer​ Hi William Rinker, I would insert a second Rectangle with the desired color over the gray one you have. Then you can use on the blue rectangle the Fill Animation like you did. n </s>
<s>[INST] TrendPro Summary: DocumentationThis feature does not seem to have much documentation. I found a short video that does not show much. The manuals barely mention it. Searching the forum does not get one hit. The knowledgebase only deals with bugs and passing mention. It seems like the help is the only source. It is OK but kind of sketchy on a few things. Has anyone found anything good? [/INST] nan n </s>
<s>[INST] How to Print or Export Logix I/O Tree Configuration Summary: Can Logix I/O Tree Configuration be exported or printed?Can Logix I/O Tree Configuration be exported or printed in order to document hardware in PLC redundant chassis and remote I/O racks? For example by using, RSLogix500, RSLinx, System Ferret, or some other tool. The RSLogix5000 export feature does not quite capture all pertinent information about the module types, and I don't see how to get that out of Linx or System Ferret. Also, RSLogix5000 Generate Report does not allow printing of the I/O configuration. the attached image shows desired information (e.g. [1] 1756-IF8H/A....) [/INST] In your particular case, RSNetworx for ControlNet could generate a very detailed network report, down to the Minor Revision of every piece of hardware present on the browsed subnet. Is this available for Ethernet as well as Controlnet? TJ McDermott said: Is this available for Ethernet as well as Controlnet? Yes. If you open RSNetWorx for ControlNet or RSNetWorx for Ethernet, open the network application file (e.g. *.XC or *.ENET if not already open), then select File/Generate Report to create an html report of your network application. You can then save this file as html or txt format. I highly recommend system ferret for this application. It'll generate a nice excel spreadsheet with all this information. Thanks dmargineau and Ikarimaru. Both methods produce great reports, but the best method really depends on what information is needed and what information is easiest to arrange once captured. For my case, I found system ferret was best, but others will find RSNetworx suits their needs better I'm sure. To me, ferret produces data that is better suited for tables and spreadsheets, and NetWorx generated data would be better for reports. I had used system ferret before, but had marginal results because some I/O modules did not appear to be reported. After the suggestion by Ikarimaru I played with ferret and found what works best. My system architecture uses redundant PLC chassis with remote I/O. Each PLC chassis has 2 ENBT cards, for a total of 4 ENBT cards per redundant chassis pair. Then I have 18 PLC applications and 72 ENBT cards in the system (18 x 4). An example of the IP addresses for one PLC is *100, *101 (reserved), *150, and *151 (reserved). All but two of these are under one Linx Ethernet driver. So in system ferret, if I selected the Linx Ethernet driver containing the 72 ENBTs, and either Level 6 or 7, system ferret usually did not report all of the PLC and I/O modules under EVERY IP address for a redundant PLC chassis pair. For example, no I/O was reported for IPs *100, *101, and *151, but it did report them under *150. This just made locating I/O for a specific redundant chassis pair more tedious. It seems like ferret just picks one of the four IP devices within a redundant chassis to create a report for that chassis, but the IP device ferret chooses is random (e.g. not always the first, second, third or fourth IP device in the redundant chassis pair). So, what really worked well using system ferret was to select a specific IP address for the ORIGIN in ferret instead of selecting the driver containing ALL of the IP devices. IF you do not have redundant chassis pairs you will not need to be bothered about this. n </s>
<s>[INST] Is this an activation problem? I have installed FactoryTalk View Studio v5.1. When I try to open an application the scroll bar gets to loading services and stops.I have reinstalled two times with no warnings or errors. We have this running on two other laptops with no issues. Is this an activation issue? I am running XP pro with Service Pack 3. I have attached a screen shot. [/INST] Not necessarily :smileytongue: Try first to see if Aid 39501 could help.... - fuzzy logic So i just did what that aid document said with the same results. It freezes at loading services everytime. Wow.... :smileysad: Just add some other infos please... :smileywink: Does it happen opening all applications ? Also sample projects ?What about the New projects ? Anyway, the only Activation related problem I remember is explained in Aid 36198, but I don't know if it applies to your issue... :smileysurprised: - fuzzy logic The same thing happens when I try to open a old application or a sample applilcation. When I try to open a new application I never get any scroll bar at all it just locks up. Should I do a add/remove uninstall and start over? Ok so I just rechecked the RSLINX Classic Install log and found two errors. I have attached another screen shot. It will help if you identify which package you are working with as both ME and SE have ver 5.1 .. and opening a project developed in one does not guarantee you can open it with the other package. When you install the software there is a preferred order of what is installed or uninstalled... jumping past steps is a bad thing.. Sorry. I am running ME 5.1. The only applications I have tried to open are ME apps. I think I am going to do a complete uninstall then go back throgh the installation process again. I didn't skip any steps in the installation process So uninstalling everything and reinstalling didnt help the problem. Anyone have any guesses? Should I roll-back SP3 and reinstall that? Hmmm... my suggestion here is to call in Tech Support guys, they may guide you to do a clean manual uninstall of your FactoryTalk View ME... I've solved some problems in the past with this procedure, hope the same for you ! :smileytongue: - fuzzy logic I just uninstalled alot of old programs and competitors software and such. Now I am getting a rsdbgutils.DLL file not found error. I am going to try reinstalling it one more time. Not a known Activation's Problem.I have seen that behavior when there is a problem with the FTSP security.Unfortunatelly because it's a security thing, I can't post the data here. I suggest that call into support where they can walk you through getting this cleaned up. Well it sorta works now. After I boot my PC I have to go into add/remove and repair FactoryTalk Services Platform 2.10 I can then open an applilcation. Although once I close FTV Studio I have to restart the PC and repair FactoryTalk Services again. I am going to call support later to see what I can do to fix this. Well I guess you could say that it is solved. I formated my laptop and reinstalled everything and everything works now. n </s>
<s>[INST] Ultra5000 firmware upgrade and Logix 5000 Hi, I've been asked to upgrade / reinstall the firmware and then possibly the application on an Ultra 5000 motion controller after what looks to be corrupt firmware. I haven’t had anything to do with these motion controllers before I'm lead to bereave that I can use Logix 5000 to reinstall the firmware and then reload the application. Can anyone confirm the basic procedure / steps that I can expect? What version of Logix 5000 do I need to be running? (I have version 10, 11, & 13 loaded at present). Thanks in advance. [/INST] You cannot use RSLogix 5000 to upgrade the firmware. The Ultra5000 is a stand alone servo drive/controller and you will need to use Ultraware software. n </s>
<s>[INST] RSLogix 500 Pro not properly installed. message I have been using RSLogix 500 Pro for years. This year, after re-licensing, I get a message that says This product is not installed properly. Please uninstall and reinstall.. Uninstalling and reinstalling does not fix the problem. I initially tried installing the latest version from the toolkit. That didn't work. I downloaded the latest version from the website. That didn't work. I called tech support. They said there wasn't a fix. What do I need to do to get the software to run on that computer? [/INST] Could you give some more information, that will help us to help you.What is the operating system and service pack you are using?When does the error occur when you attempt to launch the application?Are there any other error codes or text included in the error message?What other Rockwell Software and versions do you have installed?Does your other Rockwell Automation software launch ok? I'm running XP Professional SP3. The message appears when I try to start the RSLogix 500. The software doesn't start. I have not seen any other error messages. I've checked event viewer under Application and FactoryTalk Diagnostics. I have RSLogix 5000, RSNetworx, View Studio, RSView32, RSLogix 5, RSLinx Classic Pro. We are a systems integrator and get the RSRevs Toolkit every year. Did you already see technote 52399 ? Also have a look to the Support Matrix for Rockwell Software, check if your versions are tested to work with XP sp3. - fuzzy logic n </s>
<s>[INST] Is it possible for a dynamic alarm message in FT View ME ? Hi, I have five control panels with same PLC program. And here is my below requirement: while displaying the Alarm message for each control panel the initial Tag no to be shown differently. For example: Panel 1: Alarm Message: PZT-10101 : Suction Pressure High High Alarm Panel 2: Alarm Message: PZT-11101 : Suction Pressure High High Alarm Panel 3: Alarm Message: PZT-12101 : Suction Pressure High High Alarm Panel 4: Alarm Message: PZT-13101 : Suction Pressure High High Alarm Panel 5: Alarm Message: PZT-14101 : Suction Pressure High High Alarm the difference is only the numbers highlighted. So is it possible to change dynamically, so that i can have only one backup file instead of maintaining 5 backup files. Note: The PLC program remain same, means the tag linked to the alarm is same, only i need to show the message differently. Thanks. Vijay. [/INST] Vijay, it sounds like you have a single Panelview+ collecting alarms from five PLCs. Is this correct? If it is, you have five separate shortcuts in Linx Enterprise. You'll end up with unique tags from them no matter what. Using your example, each PLC is going to send a tag, say PZT_HIHI. the connections you would use in ViewME would look like this: {[panel1]PZT_HIHI} {[panel2]PZT_HIHI} {[panel3]PZT_HIHI} {[panel4]PZT_HIHI} {[panel5]PZT_HIHI} Your PLCs will still have the same identical programs. TJ McDermott, Its five different PVP6. It like, I have 5 compressor skids with PLC & HMI. All the P&ID, Control Sequence is same for all skids. Only the field device tag names are different. So we maintained PLC program same for all panels. Actually by scenario I have to maintain 5 individual HMI programs as I need to show the device tag names as per the skid. So Now I'm trying to avoid 5 backups instead want to maintain 1 backup for HMI also. Thanks. Thanks. Each skid has its own PLC and HMI. Each skid has unique sensor names. Technically, that makes each skid unique and needing separate programs. You can keep the programs generic and put the sensor names in PLC string tags read by the HMI, and editable through the HMI. I think that's the best you're going to be able to do. If a new skid is commissioned, then the person starting it up would have to enter the various unique names into the HMI to individualize the skid at that time. If an existing skid's PLC crashes, it would be as if you were commissioning a new skid when replacing the PLC. No matter what, somewhere along the way, you have to enter data that makes the skid unique, makes the program different. n </s>
<s>[INST] How to forcibly reset counts in a 20-750-ENC1 encoder option Summary: Is there a programmatic method to reset the current count of the encoder board? This is a motion application using a CIP-Motion PowerFlex 755 drive with a standard incremental encoder.. In general it works quite well. But the trend of position and velocity that I've been watching worries me at times - velocity becoming ragged and unstable at times.. Passive rehoming of the axis doesn't reset the underlying encoder count, but I may have one of the setup options wrong for doing so. My Axis Travel option is set for Unlimited, therefore the Unwind option isn't available for setting. It's configured this way because that was the default - and I didn't mess with anything that didn't appear to need messing with. As the encoder values increment toward very high integer values, the velocity trace (on a trend) becomes increasingly ragged. Restarting the drive causes the encoder to reset to zero, and the raggedness disappears. My theory is that encoder values that correlate into floating point values (positions and velocities) begin to lose numeric precision when derived from very large integer values. There may be a variety of more elegant ways to solve the problem (and I'd be interested to hear them all), but my brute force method would be to just reach in and reset the encoder. Is there a way to programmatically control the encoder board's count? Is it through an SSV? Or a motion instruction? Or explicit message? Or some other clever thing that hasn't occurred to me? My exact application configuration is contained in an earlier post. The sparseness of this post is an attempt not to be redundant with those details (if relevant). Thanks [/INST] I'd try MRP (Motion Redefine Position). A good thing to try! I'll give it a whirl. Thanks. You are not resetting the actual count of the card. With CIP motion, you're working within the processor. MRP and MAH both stay within the processor, affecting positions based on user units. TJ, There's an old Unix phrase that you might have heard... Obey me! I am 'root'. That's what I'm trying to get this encoder card to do. With CIP motion, there are actually two loops, a slow one that operates on the coarse update. The inner one runs on the drive. The processor is in control of them both, either directly or indirectly. The encoder card probably only comes into play for the inner loop, so It's certainly further removed from the processor. However, the motion axis takes very assertive control over drive parameters, and disallows a lot of tinkering around from external tools (such as CCW). My suspicion was that a method exists to manipulate the counter card, either directly or indirectly. It's entirely possible that my operating theory is wrong, and that I really don't need to concern myself with that count. What I do know is that cycling power to the drive makes motion considerably less erratic, while longer periods of continuous running cause motion to become increasingly so. I should modify that statement to say that my observations indicate that. My observation tools may be a contributor to the effect that I'm investigating - but I don't think so. This, being my first attempt at CIP motion, makes me vastly more attuned the things that look like oddities and anomalies. Thanks for joining the discussion. Mike Mr. Pebworth, first question that LEAPS to mind is: What firmware are your PF755 drives at? Until Firmware V6, there was significant bugs having to do with Ethernet communication causing what looked like bad tuning. Cycling power fixed it. If you are not at their current version (9, I think it is THIS month), I would try that before anything else. Second, again for noisy motor/drive, the coarse update period cannot be too low. What it SHOULD be for PF755s is poorly documented - 3ms is the bare-bones minimum. With just two axes in one of my systems, 6 is the lowest I could go, and i think we settled on 8ms. Going lower causes the motors to sing; we wasted a man-day trying to tune it out before increasing coarse update as a last resort. As to your question, when in CIP motion, as far as I know you do not have the ability to reset the card-level position. CIP motion means you're working through a conversion constant; the raw count gets converted to user units and that's that. I cannot stress getting past the early firmware enough. My revision is 7.1. That may indeed be older than I want. My coarse update is 2.0 mS, and this is, so far, just a single axis system. An interesting point - as you raise the comment about noisy motor/drive - is that the motor doesn't hunt or oscillate or buzz/squeal. My only indication that something is afoul is my plot of velocity. It gets a bit worse than in this example below. To be honest, that doesn't look TOO bad for a 755 in CIP motion. However, your coarse update period is definitely too small, even for a single axis 755. For Kinetix 6500 (also Ethernet CIP motion), I think that's ok. PF755 drives must have a minimum of 3ms. That is documented (somewhere). To be safe, I'd suggest 4ms as a starting point and see if the velocity smooths out. Thanks, I'm going to set up a test bed version of it so that I can tinker without having to wait for time on the production line. I'll try your suggestion. Mike n </s>
<s>[INST] Problems with concurrent activation I downloaded my concurrent license from internet but it the activation tool does not recognize it. I installed the activation server but it only sees and old node locked license and stills remains with a server direction of an older license that was borrowed from a server. I really need help because i can't activate my products because the activation tool doesn't see the license. Help please. [/INST] Start with checking that the licence file is present in the folder path set in the Settings tab of the FactoryTalk Activation Tool for the Folders searched by a local activation server. Make sure that the path ends with the character or the server does not detect the license file.Check that the license file name has a single extension of .lic If that doesn't work then call Tech Support or refer these tech notes 37686 - How to set up a FactoryTalk Activation Server using FactoryTalk Activation Tool (Version 3.02)http://rockwellautomation.custhelp.com/app/answers/detail/a_id/37686 35092 - The FactoryTalk Activation Server can not be startedhttp://rockwellautomation.custhelp.com/app/answers/detail/a_id/35092 35251 - FactoryTalk Activation Frequently Asked Questions. (FAQ)http://rockwellautomation.custhelp.com/app/answers/detail/a_id/35251 I have been trying to get activation help for almost two weeks now, have had help from several tech support people and still have software that will not activate. Hi Jeff, I understand your frustration, but writing here just to complain, maybe will let you feel better, but doesn't solve your problems... :smileywink: Post instead a description of your issue, maybe somebody here will be able to suggest you something... - fuzzy logic n </s>
<s>[INST] FactoryTalk V10 Upgrade Hello Y'all I have FactoryTalk View Studio Ver. 8.00. When I try to upgrade to Ver10 I am only see Ver 8.20 that is available, do I need to purchase Ver10? Thank Randy [/INST] Hello Randy, Licenses can be upgraded to latest versions when put under TechConnect contract with your Local Distributor. Hi Randy Shepherd, As far as I know you need a registered License Key, that is within a Tech Connect Contract to download the latest Versions. When you can only Download older Versions, it seems your Tech Connect ran out or version 8.20 was the newest version at the time your serial key was sold and registered. Please get in touch if you have any further questions. If this answer helped you, please Like. If this answer is the best please REPLY-> Make Best Answer n </s>
<s>[INST] Kinetix 350 - 2097-V33-PR1-LM Incoming power supply Summary: Can the Incoming power supply support Single phase 230V AC Hi, I am a new user of Kinetix 350 - 2097-V33-PR1-LM. I purchased a new drive. When seen on the Mains connector side its say Single phase 120V or three phase 240V. I use the Motion analyzer software to finalize the part number. The software says we can use it as Single phase 240V incoming power supply. In actual Can I power it on with a Single phase 230V AC? Thanks, Gowri. [/INST] Yes, see the table below. - fuzzy logic In order to enhance Forum's contributors reputation, please rate the replies you got and remember to close the thread clicking Choose as Best Answer button over the solving answer. Thanks ! Thanks, for your fast reply. Thanks again n </s>
<s>[INST] Activation issues after System Restore I successfully activated my RSLogix / Studio 5000 and saved that to the dongle. But when I attempted to install version 31 to the laptop, it failed at VS 2015 setup. After trying to resolve that problem, I performed a System Restore. The only image I had was to a point right before the activation, so that was rolled back as well. Now, after the restore, RSLogix 5000 reports not activated, and FTA does not show my activation. When I try to get new, and enter my SN and PID, I have 0 of 0 activations available. I am stuck. Shane [/INST] First, some brief questions. Windows Version FTA version Dongle type/color Depending on the anwser, I'll provide you with the data that can help :D Windows 10 FTA version 4.03.11 green dongle. Thank you! Shane edit - spelling Sorry for the long wait. Windows 10 - I would recommend updating FTA to v4.06.13. When it comes to Green Dongle - this is a Flexera dongle, does it have memory like an USB memory stick? Other than that, try installing the Dongle USB drivers - FactoryTalk USB Dongle HASP Key and Drivers Hello Mr. Freitag, and thank you for your reply. So the problem was the dongle I am using does not have storage in which to save my activation license. Therefore, when I rolled back my system, the .lic file was lost. (I have since requested a dongle WITH storage.) The competent folks over at TechConnect Activation support hooked me up with my license file, and I saved it to several safe places, so, if the same scenario presents itself, I will be able to recover from it (in case my management doesn't want to buy me the better dongle, but I think they will ;-) ). Another lesson learned! Shane For the same reason we have discontinued the sales of Memory-Less Dongles :D. New dongles will always have memory, so if you upgrade to new dongle, you will be set for the lifetime of dongle. n </s>
<s>[INST] ASCII value from bar code scanner into RS Logix 500 programming environment Summary: Request for programming hints on reading a ASCII valueI am trying to build an inventory management system that receives part numbers(Format, 123-45:67) from a bar code scanner and uses Allen Bradley 1100 PLC to keep a track of parts in stock . I require some help/hints on programming steps, to detect when there is a new bar code scan; write the value (part number) through Channel 0 and store in a string and clear buffer for next barcode scan. I do understand that key is to use ARL instruction but I can not figure out how to trigger a false to true transition for the same, as there is no traditional input in this case. [/INST] Suresh, Per my realize as below. MicroLogix 1100 will store the data in the buffer if the scanner sends the data actively. So you need to use ABL or ACB instruction to check is there any data in the buffer and is the data as expected length. Then you can use ARD or ARL to read the data. Once the data was read by the instruction, It will move out from the buffer. n </s>
<s>[INST] How can add PF40 driver database in Rslogix5000 v13. Use 22comm-e to talk with PLC. There is not driver database in Rslogix5000v13.I know PF40 databsse already build in v16. If I stay with V13, How should I do?Is this addin file available? [/INST] If you are going to keep using RSLogix 5000 version 13 (if you have a 1756-L1 controller, for example) you will not be able to use any of the Drives Premier Integration features introduced in version 15 and 16. Instead, simply use the Generic Module method for connecting to the 22-COMM-E, and use DriveTools or DriveExplorer separately to configure and monitor the drive. It is not as convenient as Premier Integration, but it works. You can address the I/O words for the Generic Module directly, or copy them into and out of UDT type tags that you have created to match the 22-COMM-E I/O structure. Thank for the reply.Generic Module method you meam explicit message? But you still need see the driver in Rslogix5000 in order to input the hardware path in the Command MSG. No, explicit message is another beast.... Generic Module is simply an I/O connection for which you have to define manually the connection parameters, for those modules that aren't available with a pre-installed I/O profile inside the RS5000. Follow the instructions inside the 20-COMM-E User Manual, chapter 4. - fuzzy logic n </s>
<s>[INST] One .mer file for 4 Panel View Plus Terminals with Global Connection Tags I have a situation - One .mer file for 4 Panelview Plus 7 Performance Terminals and Replacing the Screens from PLC using Global connection tag. Sometimes HMI Terminals are get stuck in one screen, to avoid this i would like to check the other options with a macro? How to overcome this issue ? [/INST] This is how we push an Alarm Screen to the front using Global Connections. Reference Attached. I'm moving this thread to Automation Control, where it is better suited. If you are not already a member of the Automation Control community and want to continue this conversation, you will be prompted to join that community. Thank you, fuzzy logic Please don't forget to use the LIKE button and highlight the decisive answer : REPLY > Make Best Answer​ ​ n </s>
<s>[INST] FactoryTalk ME - Recipe Hi all, I have the following requirement in a Recipe. I have below sets of Recipes for a CIP Process with 50 Units each Recipe Units Line 01 Acid Line 01 Acid - Tank 01/02/03/04......50 Line 1 Lye/ Line01 Lye - Tank 01/02.../50 Line 1 Lye Acid Line 01 Lye Acid-Tank01/..50] Line 02 Acid / Line 02 Acid - Tank 01/02/03/04......50 Line 2 Lye/ Line02 Lye - Tank 01/02.../50 Line 2 Lye Acid....... Line 02 Lye Acid-Tank01/..50 when i use recipe+ in FTViewME I get these recipes in the tables. But i want two sets of tables shows only one set of Recipes or Selected set of Recipes in the Table. (Line 01 Acid/Line 01 Lye/Line 01 Lye Acid and its units in a separate recipe table set and Line 02............ Recipes in another set of Tables) Is there any possibility to do so... Please drop a quick reply. Thanks [/INST] Good Morning. Unfortunately there is no possibility to do this as the recipes are stored in a single folder location and there is no method to filter the recipes contained there with the recipe objects. n </s>
<s>[INST] Cursor location on PV+ Hi is it possible to return the touch location (cursor) to the PLC? [/INST] I really think this isn't possible... I 've never heard about this info to be available :smileysurprised: - fuzzy logic n </s>
<s>[INST] RS500 With FT Activation Manager we have rehosted our Studio5000, Factory Talk View, and RS500 license . Then set up the path and renewed them to a central server. The Studio5000, Factory Talk View work properly but the RS500 does not see the license and goes to the 7-day trial mode. If I look at the About RSLogix 500 it still shows the old license Serial [/INST] Hi John, serial numbers in the FactoryTalk Activation Manager and in the system registry (the serial number you can read inside the About) must have the same 4 first digits (prefix). Is that condition verified? If answer is yes, which are the 4 first digits of your serial number? fuzzy logic Please don't forget to use the LIKE button and highlight the decisive answer : REPLY > Make Best Answer​ n </s>
<s>[INST] L61 with Multiple ENBT cards - optimizing ethernet comms Summary: Is there still only one comm bufferI am working on large (to me) telemetry project where there are multiple comm channels on different networks that all need to be MSG'd to . Cellular Ethernet 2 Hardwired subnets Ethernet Radio 19.2 baud Serial Radio 19.2 Baud (will eventually be obsolete but not for years) I will need multiple Ethernet cards of course but I need to know if there is still the same single COMM buffer restriction that I always seem to fight. In other words, do I need to sequence every MSG with .DN bits like I do with serial comms? Or are all the ports parallel with their own buffers so I can blast away independently? [/INST] nan n </s>
<s>[INST] FT Optix Open popup on a value change. Currently I'm working on a project in FT Optix. I've been working in it for a while now but I can't figure out how to open a popup in the runtime when a value changes. In the PLC there is some code running and when this is done, a value changes, when this value changes the popup needs to open. This popup should be able to open on every screen on the foreground. [/INST] If you go to the variables in your project you should see the Events section of the properties tab. You can add an event by clicking the plus sign in the top right corner of the properties tab and select Changed Event. Then you can use that event to open a popup by linking it to the UI commands for opening a dialog window (OpenDialog).n </s>
<s>[INST] Has ANYONE Successfully Sent An Unsolicited Message From An SLC 5/05 To RSLinx? Just spent an hour and a half on the phone with RA support. We all agree it looks like it should work. However, the message function in the SLC always errors out and no data is sent. I can set up a polled topic in RSLinx and everything works fine. [/INST] For those who are interested in, the user posted HERE how he has solved his issue... - fuzzy logic n </s>
<s>[INST] VBA and Tag Memmory I have a code in VBA : gTagDb(DATA).Value = 1with DATA : Tag Memmory, Tag AnalogBut the VBA allways debug : runtime error 4173, if DATA is Device Tag, it debug success.How can i write and read the Tag Memmory ? [/INST] Hi, are you using RSView32 ? I usually use the following syntax, no matter if it is a device or a memory tag, it works fine. gTagDb.GetTag(Mytag).value = 10 Just tested running the VBA code on a Button press, and works. - fuzzy logic remember to use the 'set' syntax if you want to declare a pointer to a tag ie dim mytag as tag set mytag = gTagDb.GetTag(Mytag) mytag.value = 10 'if its an analog tag the following will not work mytag = gTagDb.GetTag(Mytag) n </s>
<s>[INST] Factory Talk Problems I upgraded to the latest release of Factory Talk and have had no end of trouble since. Anytime I try to open the tag database it says An error occurred while attemptingto open the tag database editor. The program also has a tendency to lock upmaking a reboot necessary. How do I fix the tag editor? [/INST] Try to follow indications in Aid 34108 ... Hope this helps… - fuzzy logic n </s>
<s>[INST] Studio 5000: activation configuration information was invalid Summary: Getting an error message when attempting to activate studio 5000While trying to assist a customer in activating their Studio 5000 software. When they enter the serial number and product key they get the following message: Serial [/INST] The best in this situation is to call in Technical Support and have them check inside the system. - fuzzy logic In order to enhance the reputation of the Forum's contributors, please rate the replies you got and remember to close the thread clicking Choose as Best Answer button over the solving answer. Thanks ! Upon pressing validate activation, issue appearing is as following; There are no activations remaining for this serial number & product key. n </s>
<s>[INST] DDE To Excel I am trying to get data out of My compact logix to excel inorder that I can print it but I am having trouble with strings they dont appear in excel I just get the topic reference I think its a syntax error on my part but cant get it to work can anbody help please [/INST] What exactly is the syntax you are using ? Are you entering the DDE link manually in Excel, or copying it from the DDE/OPC Copy Link feature in RSLinx Classic? Is this an ordinary ControlLogix STRING data type with a default 82-character length, or one you defined with a custom length ? Do any other types of tags work in your DDE application ? Hi Ken thanks for replying I am trying to create an excel spreadsheet comprising of 1 column of string data (material Names) and 4 columns of Integer data to be printed I am using a copy DDE/OPC link from Linx I know that linx is communicating with the Logix because I can get to the online data in the copy DDE link but when I select the String tag I can only get individual data bits in the copy window the string data is an ordinary data type and of standard 82 character length I can copy integer tags across with no problem I have set the cell format to text but I am not sure this will be correct I've tested what you need, try to follow indications below: 1. Inside RSLinx, Select Edit > Copy DDE/OPC Link. 2. Expand the RSLinx OPC server (Node: <Local>), then the topic and finally select Online.3. Open the string file, for example, MyString1. There should be a default MyString1.LEN data element showing up in the list. 4. Delete the following text .LEN,L1,C1 from the Data Address field. 5. Open Excel, and select a cell. 7. Select Edit > Paste Special from the menu. 8. Select the Paste Link option, then click OK. Hope this helps, - fuzzy logic Thanks for your help I had tried all sorts of number combinations but hadn't thought of just deleting half of the data once again thanks for your help and this seems like quite an elegant way getting round the lack of access to tag data in ME n </s>
<s>[INST] Powerful 4 E-STOP I am building a small panel with two(2) powerflex 4 VFD drives.I need to hard wire an e-stop into the drives. How do I do this?I have been told that contactors on the motors are not good and that I can't e-stop electronics. Does that mean I can't e-stop the VFD? The application is small. It runs two small horizontal conveyors. There is no major risk of stopping the motors at any point in time. My thought is to put a N/C contact in series with terminal 1 (stop). This will open the stop circuit and stop the motors. The drives will remain ON. Once the e-stop is reset, the open contact will close and the drive will wait for the start signal again from the main machine. Is this acceptable? Or will this method risk damaging the drives or motors? thank you [/INST] The Rockwell Knowledge base ID 39169 can assist. This attachment discusses the advantages and disadvantages of input contactors, output contactors and the DriveGuard Safe-Off relay http://www.rockwellautomation.com/knowledgebase/ Output contactors work very well but you also need to STOP the drive to keep it from faulting on load loss (or disable the load loss alarm). The safe-off option is really nothing more than a relay on a circuit board that either enables or disables the gating function of the drive, thus stopping it. In a simple application such as what you have here, an output contactor would work fine as long as an aux. contact enables the drive when the ESTOPs are OK. The tech note David9 refers to has great information in it, especially on the input contactor. The most important part of understanding the input contactor scenario is that the drive will run a few seconds....I've personally seen a PowerFlex70EC drive run for 12 seconds before totally discharging. n </s>
<s>[INST] Kinetix 6000 analog output monitors (0-5V) or (0-10V)? Regarding the output voltage range of the analog output monitors for the Kinetix 6000 drive series : The manuals specify a 0-5VDC analog output voltage range for the monitors. But, I have seen a number of K6000 modules that produce 0-10VDC on the analog outputs. Both IM modules and AM modules. Question : Was this specification changed sometime during the life cycle of this product? I've seen 0-10V produced too many times to think its hardware failures. Thanks [/INST] Yes, the newest Kinetix products (with part number end with -S) have the range 0-10 vdc... See the table below, taken from the User Manual: - fuzzy logic Thanks Fuzz... I had the 2008 version of the User's Manual, which didn't show this difference. Thanks again n </s>
<s>[INST] PF755 Increment /Decrement Speed using 0-10V Hi , Is it possible to increment the PF755 speed in fixed amount using a 0-10V or -10V to 10V i.e if the drive receives 10V it will increment the speed by 2Hz and if it receives -10V the speed will decrement by 2Hz . I know it is possible using DI assignment but PF755 has only one input and that input is assigned to Run and dont have a seprate I/O card . Also since it is standalone VFD control over ethernet is not possible . We have a spring return Selector Switch which if turned in one Direction speed should increment by 2Hz and if it turned to another it should decrease by 2Hz. Can i connect a analog input to the drive through this such that drive receives +/-10V and accordingly increment/decrement speed by 2Hz [/INST] Hello, as pointed out on your initial post, the implementation of that application requirement would be possible configuring the MOP (Motor Operated Potentiometer) feature of the PowerFlex 755 with the help of 2 digital inputs. In the scenario presented, it looks like there are not spare inputs available to be used, so the straight forward implementation of the MOP feature will not be possible. To my knowledge, based on the MOP block diagram below, there is no indication that the switching of a +/- 10V analogue input will be triggering the 2Hz increase or decrease sought after on this application. More information on the MOP feature is available via chapter 6 of PowerFlex 750-Series AC Drives, Reference Manual Another possibility could be exploring if some sort of drive embedded DeviceLogix code could be implemented to mimic the MOP functionality of the MOP block diagram above. As any code creation task, this could be a time consuming exercise that may pose a challenge on its own, due to the real possibility of non being able to manipulate or access certain signals/registers on the drive via DeviceLogix. n </s>
<s>[INST] How many tags per data log model :smileyhappy: Hi all!!! I am a little confuse. If I have a Distributed network, I can configure 20 data log models on a server, but each datalog could log 1000 Tags - Document: iasimp-qr010_-en-p -. But the manuals on FactoryTalk View SE say: A HMI server can have up to 20 data log models running at one time. The maximum number of tags that can be logged by one data log model is 10,000. Could you please explain my that? I want to be sure, that I am making the right configuration on my server. In advance thanks for your attention and I would be very glad to hear from you soon. Kind regards, Yari [/INST] Well, both statements are correct... :smileysurprised: The maximum number of tags that can be logged by one data log model is 10,000. CORRECTA HMI server can have up to 20 data log models running at one time. CORRECT If the second case has to be examined, you've to consider that if you run all the 20 available Data Log models, every one with 1000 tags, you need to use 20000 tags, that is the limit for a Data Server. From all controllers you may have up to 20,000 tags on-scan per data server computer for RSLinx Enterprise, 10,000 tags for RSLinx Classic, more Data servers can be added as neccessary. As per the above examples, you may have up to 2 Data Log models running at one time if both have 10000 configured tags. Hope this helps… - fuzzy logic n </s>
<s>[INST] Transferring IP Nodes from 1 processor network to another Hi, Using a dual ethernet port processor I recently had to swap all of the devices from port 1 to port 2 and vice versa. At first I attempted to drag and drop devices from 1 network to the other. This caused a problem when I opened up a ladder routine as I saw that all of my tag alias addresses had been removed. To get around this I found that the fastest way was to delete the devices already on port 2 network as there were far fewer than on port 1 network. In the processor properties I changed the Ethernet Mode to Linear/DLR, once applied, I then changed the Ethernet Mode back to Dual IP and was able to select which network that I wanted the devices to be assigned to. All I had to do then was re-create the devices that I had deleted. This worked fine but I was wondering if there was a better way of doing this? Thanks, Luke [/INST] Hi Luke, I believe that you can copy the ACD file, and to keep opened both projects, Deleting the modules in the new project and dragging and dropping all modules from old project to desired port in new project. As well as the modules will move with same name, the orphan tags will link with the moved modules. n </s>
<s>[INST] MicroLogix 1500 LRP - Intermittent internal fault Have an odd ball problem. System is MicroLogix 1500 LRP Series C1764-282BXB Base Unit1764-MM2RTC Memory Module1769-SND I/O Scanner - Communicates with Power Flex 401769-IQ16 module1761-NET ENI Problem is that occasionally the PLC loses it's mind. Only thing that shows up is that an internal fault occurred. I am not able to get a fault code from the unit. Redownload the program and all is right with the world for awhile. Awhile being anywhere from 1 hour to 2 months. Has anyone else run across this? Any thoughts on how to trap for an unknown internal error and get back online so we can at least get an idea on what is happening? Did check the panel grounding, neutral/ground bond, incoming power and 24VDC power supply connections and quality. [/INST] Your probably going to find an output going to a inductive load with no snubber at the load... or noise... both can trash/corrupt the processor program. Not a bad thought I have had that happen on numerous occasions. I checked out the schematics. They do have a solenoid with no suppression on it. We'll try out mister diode and see what happens. n </s>
<s>[INST] 1769-IA16 wiring with 1492-IFM20D120 Summary: What is the purpose of A1 and A2 in this combination? [/INST] nan n </s>
<s>[INST] RSView Alarm Suppression I have several HMIs with RSView installed. When the program is restarted it suppresses a list of alarms. If you unsuppress them they will go back to being suppressed when the program is restarted. The manual says the only way to suppress alarms is through the command prompt. Does anyone have any idea how these alarms are being suppressed? [/INST] Did you develop the program youself? or is it a running installation? i'm guessing somthing like a macro running at start up? This is a running installation. It has been in place for awhile. Everyone involved in the installation has left the company. I looked in the start-up macro but I do not see any suppress commands in it. what version are you talking about? when you look in the alarm and event server, check the alarms. and then the status tags of the aalrms. if there is a tag defined for supression. check what that tag does when the hmi is started. an other option to check the diagnostic list during startup and see when the supression is called I figured it out there was an event that was configured that suppressed all of the alarms if the boiler was tripped. good to hear you solved it! n </s>
<s>[INST] Bitwise alarms in CCW for PanelView 800 Hello, I need to setup bitwise alarms in CCW for a PanelView 800, but I don't want to define a bunch of boolean tags. In FactoryTalk View, we could define alarms to trigger from a specified bit of an integer tag. But that column in CCW only allows values of 0 or 1 when the alarm is not numeric. So then I discovered that CCW allowed me to specify the trigger as a tag with a bit number such as AlarmTag.0, AlarmTag.1, AlarmTag.2, etc. However, this doesn't appear to work in practice. Alarm messages are never triggered. Has anybody else run into this? Thanks in advance, Andy [/INST] Update... I found a work-around of sorts. I defined Boolen tags for the alarm triggers in the HMI project, which reference the appropriate bit of the integer tag in the PLC. At least the SCADA system can still reference the entire integer tag as originally intended and I didn't have to change the PLC code :-) n </s>
<s>[INST] Controllogix connection xxxxxxx got disconnected Summary: RSLinx communication events show errorsHi, There are error logs popping out in RSLinx communication events like what is shown below. I'm having a hard time locating the problem when all connections are normal, no sign of disconnection, all communication modules are functioning properly. I'm using EN2TR and Etaps in DLR: four L6 in different chassis, two remote I/Os. I noticed the IP addresses of those persistently showing disconnection are ones with controllers, remote I/Os never show disconnection. Looking forward for your help. AB_ETH-10.(192.168.1.30).1.2 : -none- : 06/05/17 - 22:17:46 : 00h Items: -none- Type: READ Mfg: Allen-Bradley PlcType: Logix5000 Desc: ControlLogix connection 5853127 got disconnected. Number of occurrences: 1 Last Error occurred: 06/05/17 - 22:17:46 AB_ETH-10.(192.168.1.10).1.2 : -none- : 06/05/17 - 22:19:44 : 00h Items: -none- Type: READ Mfg: Allen-Bradley PlcType: Logix5000 Desc: ControlLogix connection 5994145 got disconnected. Number of occurrences: 1 Last Error occurred: 06/05/17 - 22:19:44 AB_ETH-10.(192.168.1.20).1.2 : -none- : 06/05/17 - 22:22:39 : 00h Items: -none- Type: READ Mfg: Allen-Bradley PlcType: Logix5000 Desc: ControlLogix connection 5995823 got disconnected. Number of occurrences: 1 Last Error occurred: 06/05/17 - 22:22:39 [/INST] Kindly help me on this. Thank you n </s>
<s>[INST] downgrading mer file from 64 bit to 32 bit Summary: mer downgradeHi all we recently done some work with a company to add some equipment and modify some others all with AB equipment. We left copies of our work for the site engineers to use as back up files. However, we have been informed that the site engineers cannot open the files we left as these have been produced with our 64 bit PC's. Is there any way we can downgrade our saved work for use by the sites 32 bit machines. [/INST] Paul, Rockwell has made it hard enough as it is to go from 32-bit to 64-bit. There's a crazily cumbersome tool which must be run first on a 32-bit machine, then on a 64-bit machine, to bring an old application forward so it can be opened in modern versions of View. It is easier if we build a machine to go backwards in time than to do what you ask... What firmware version are the PV+ terminals? What version is the MER file you left them? What happens if you save your application down to Version 5.00 (the lowest that ViewME V9 will go)? If you send your customer that MER file, can they decompile and open it? The place to which Rockwell has driven us is that your customers should upgrade those 32-bit development computers to be something more equivalent to yours. Hopefully, someone here has a better idea, but I can't think of one. ViewME is the devil when it comes to long-term support. It would have been nice to be warned in advance that Rockwell was going to do the 32-bit / 64-bit database switch. Like, right when they started considering the idea so we have a year to prepare... Hi TJ Thanks for your response. We have found a solution which could be useful to others. Solution On 64 bit machine create runtime file to V5.0. Then close file and create an archive file. Send archive (apa) to 32 bit machine. On 32 bit machine restore archive. Then create runtime file to whichever version you require. Very long winded but hey it gets the job done. May be useful to others in the same position. Again thanks for your quick response. We did raise the question of the client upgrading to 64 bit machines but this didn't go down to well as they have 25 machines (25 new laptops ouch). n </s>
<s>[INST] MicroLogix 1500 LSP Summary: Major Error S:6 = 9h Internal Hardware errorFound MicroLogix with a fault light on. Connected with RS Linx configured no problem. Cleared fault and found ladder logix on processor blank. Reinstalled backup program and switched to run. Processor ran for three control cycles and then faulted out again . During these three cycles the processor was able to exchange data with the main scada on dial up. Notice some of the output functions were not working. Also replaced the 3.6 volt on board battery. [/INST] Welcome to the Forum ! Please note you're posting inside the wrong Hive; there is one dedicated to PLC, SLC and Micrologix, where you've more chances to be responded. Anyway, take a look to the following technote: 16301 - Fault codes 0001H, 0002H, 0007H, 0008H, 0009H caused by improper installation or noise - fuzzy logic In order to enhance the reputation of the Forum's contributors, please rate the replies you got and remember to close the thread clicking Choose as Best Answer button over the solving answer. Thanks ! n </s>
<s>[INST] Meaning of Displayed current value on VFD Hi, I'm using PowerFlex40 VFD to drive a 3 phase induction motor. I have a basic doubt. In VFD display parameter d003 output current is shown. Now My question is which is this current. I can connect motor in STAR or DELTA configuration and current will be different in both the cases (I mean Phase and Line current values). Also there are three windings U,V and W in motor. So is it the case that VFD is delivering same current to all 3 Motor windings (just 120 degree apart ) and it is that current ? Also is this the RMS or PEAK or AVERAGE current ? [/INST] Hello, d003[Output Current] is the total output current present at terminals T1, T2 and T3 of the drive, as measured and calculated by the internal drive circuitry. The total output current can be defined as: where Torque Current is the amount of current in phase with the fundamental voltage component and Flux Current is the amount of current that is out of phase with the fundamental voltage component. Torque Current and Flux current are not available from the PowerFlex 40 drive (there are other drives from the Rockwell portfolio that provide feedback on Torque Current and Flux Current via read only parameters). It is expected the value of parameter d003 [Output Current] to be different depending on the internal arrangement of the motor windings (STAR or DELTA). Those values should be in accordance with the relevant formulae for voltage and current in typical Start and Delta motor connections. Please note that the drive will not be aware of how the motor windings are internally connected. The drive will be able to provide an output voltage up to the same level as the supply voltage (the drive will not be able to provide more voltage out than the voltage coming in). It is important to check the specifications of the motor to make sure that the motor windings in the desired connection (STAR or DELTA) are rated and capable of withstanding the output voltage provided by the drive. The inverter section of a variable speed drive does not produce sinusoidal voltage waveform, but rather a series of voltage pulses created from the DC bus, also known as PWM (Pulse Width Modulation). More information on this can be checked via this document Induction Motor Winding Voltage and Inverter Drive Output Voltage Relationship Those voltage pulses will be applied to the motor windings and there will be a flow of current from the drive output terminals T1, T2 and T3 through the inductance of the motor windings. The value of parameter d003 [Output Current] is provided in Amps with two decimal places. This value is filtered by the internal electronics of the drive and is an averaged value of the real time PWM current waveform. Hi, Thanks for your reply. Can you just confirm whether it is RMS of the current or Average of current ? Also, As we have only one current value on the display so is it safe assume that U,V and W has same current and that value is shown on display. Regards, Bitesh Parameter 003 [Output Current] measures the total output current present at T1, T2, and T3 (U, V, and W). n </s>
<s>[INST] NEW: Stratix 4300 Remote Access Router released The Stratix® 4300 Remote Access Router is part of a complete solution, which also includes FactoryTalk® Remote Access™ software. Together, these products make the Remote Access for Industrial Equipment solution. This connectivity provides support for installation, programming updates, and on-demand troubleshooting and maintenance when you cannot travel. The Stratix 4300 router is designed to allow machine builders and OEMs to securely operate on remote systems and its subnetworks. The secure remote access routers are offered in two and five 10/100/1000 Mbps Gigabit Ethernet copper port variants. See HERE for available documentation. fuzzy logic Please don't forget to use the LIKE button and highlight the decisive answer : REPLY > Make Best Answer [/INST] Fuzzy Logic - Thanks for sharing. I am excited to hear any use cases or user experience with this appliance and/or the FT Remote Access separately on an IPC. I am assuming a use case is a ThingWorx application running on top of the on prem or cloud databse? I saw this for Ewon and assumed that would certainly apply to this appliance as well. Dan - Great question! Our solution for Remote Access for Industrial Equipment (using FactoryTalk Remote Access and the Stratix 4300 Remote Access Router) is really intended for VPN access to a machine, rather than data streaming. For data streaming to ThingWorx or other applications, I recommend looking at FactoryTalk Edge Gateway. Thank you for the clarification! And I can run FT Edge Gateway on a Box, Panel, or IPC so that is a great option! n </s>
<s>[INST] Unwind/Winder Application I have an application that currently has two unwinds, idlers and a winder. Basically, it is a machine that takes two unwind rolls and glues them together to wind them. I am looking at replacing the current air/disk brake control on the unwinds as well as the main drive. There are two load cells that control tension for each unwind and then the main drive runs as the winder. We were looking to replace this control scheme with Kinetix 6000 but I have never done a servo web handling application. Does anyone have any recommendations or concerns? I have dealt with unwind/winders with dc and ac drives but not servos. The customer wants servo control to keep things are pricise as they can get.. Any help would be appreciated.. Thanks, [/INST] Just a few thoughts, the servos have several different configurations that might help you. You can have the loop control position, speed, or torque. So for example you might control torque on the unwinds to provide resistance to the winder, which would be controlled by the load cell. Or you might run it in velocity mode and adjust the speed based on the cells. Another interesting option would be to run the axis in Dual Position Servo mode. You would use a small encoder on the load cell, assuming the arm moved radially like a dancer. This aux encoder would provide the position reference. So you set the move instruction to go to a specific dancer position, and the servo will automatically adjust the speed of the unwind accordingly. You'd basically be using the drive firmware to control the loop rather than something running manually. Many ways to tackle this. i have the same issue but im using air brakes on unwinds and a dc drive motor on rewind. i am having trouble with the air guage making extreme changes like ( 10lbs to 40lbs ) back and forth.. it shows to be doing the same thing as the trandeucer input as far as how quick its moving. what i would like to know is how can you make to input of the load cells more stable to where the numbers can be slowed down to where that would slow down the air pressure. i have tried everything i know to do. i am using rs logix 500 on a slc 504 control.. any help would be greatly appreciated !!!!!! thanks kevin :smileyvery-happy: The first thing is which control method you do using DC or AC drivers,I think if you want to use servo system for this application, To run under the Velocity mode is a good method. Best Regards House n </s>
<s>[INST] Cleaning agents and PanelView/touch screens/Versaview The facility is reviewing the use of cleaning agents and their use on our automation HMIs in a bio-tech facility. Is there any resource on which agents to use/not to use on Allen Bradley HMIs and Monitors? [/INST] Try to take a look to the following technotes: Aid 37485 - Aid 22501 - Aid 28400 User Manuals or Installation Instructions reports (sometimes :smileysurprised: ) these informations... Hope this helps… - fuzzy logic n </s>
<s>[INST] Rsview Tag Display shortcut? Does anyone know if there is a way to display the tag that is assigned to the button/object by simply just hovering over the object. Kind of like how you would inside panelbuilder, example below. I want to do something similar in Rsview. [/INST] Unfortunately, as of actual version 5.10 of FactoryTalk View, there isn't such a feature. :smileysad: - fuzzy logic n </s>
<s>[INST] configure 1756-CNBR/E as CNBR/D On our ship we have a redundant network of 9 PLC units. All communication cards are 1756-CNBR/D Rev 5.45. We have 1 spare control net comm card 1756-CNBR/E Rev 10.7. The system is running under RSLogix 5000 Version 13.03. I would like to configure the spare card as 1756-CNBR/D Rev 5.45 so that I have a compatible spare part that is plug and play in case there is a problem. I have made a setup of backplane-power supply and the 1756-CNBR/E card. To this I connected my laptop via a 1784-PCC card and running RSlogix5000 / RS Linx When I start RSWho I can see the comm card, but it is 'unknown'. When I start Controlflash (downloaded latest version comms bundle 10_03_08), all I can do is upgrade to version 11.2.3 I can not see the firmware versions of the 1756-CNBR/D, although the catalogue number 1756-CNBR/D was selected. He only sees the latest version for the 1756-CNBR/E. Has anyone been confronted with this before? Can anyone please explain me how I can : 1) see this card in a correct way and not 'unknown' 2) reconfigure it as a 1756-CNBR/D Rev 5.45and see the backplane . using my setup (backplane-power supply-card-1784-PCC comm. card and laptop). I can not interfere with the existing network of the ship for doing this. Thanks. [/INST] 1) To see the card you should install the right EDS file which can be found at http://www.ab.com/networks/eds/ Use the EDS Hardware Installation Tool to install this EDS file 2) You cannot flash from one series to another (i.e Series B to Series C or D) with the exception of series A and series B modules, which can be flashed between series A and B. In this case you should first see the card in a right way in RSLinx, and this can only be accomplished with the right EDS file (see point 1) Just a couple of notes.... 1. I suggest to upgrade CNBR to latest firmware available2. Carefully read technote 36453 for rules/limitations on using series E to replace older modules. - fuzzy logic n </s>
<s>[INST] RSLogix 5000 TON Enabled but not Timing Summary: RSLogix 5000 TON Enabled but not TimingHave had a repeat issue with some timers involved with motion control on a 1756-L73 Controller with Firmware revision 19.13 Have had 2 recent repeat issues with a timer. During the rung execution a timer will enable but not start the timing process. Added some test bits to make sure that the rung was being scanned and active. Only after cycling the processor from RUN-Programming-RUN was able to clear the issue and have the timer start timing. Wondering if similar issues have been noticed before and if there is any firmware updates required or if the processor is just getting old, around 10 years old. Strange that for both occurances of the issue it was the same timer that had this issue. [/INST] I've never seen that be a legitimate glitch. Normally, I would think the timer tag was being used elsewhere. If a cross-reference doesn't show anything unexpected, try a new tag entirely in case it's being written to externally. n </s>
<s>[INST] Modbus TCP AOI using Modbus Gateway Hi, I plan on using a CompactLogix to communicate with a 12 module - 48 zone heat control system (Modbus RTU). Before I start, the reason I have veto'd using an Ethernet/IP <-> Modbus RTU gateway is because my application will require far more than 100 commands which seems to be what most gateways offer. My plan is to use the Modbus TCP AOI to communicate to a Modbus TCP <-> Modbus RTU gateway that will talk between the heat control system and the PLC. I was wondering if anyone had experience with this. Is the setup of the gateway important? (Whether it acts as a Modbus TCP server or client) or will any Modbus TCP <-> Modbus RTU gateway work? I've found multiple videos on people using the AOI for Modbus TCP <-> Modbus TCP applications but am unable to find any information on using the AOI to communicate over 485 with a gateway. I noticed in the Client AOI there is a Station ID included in the transaction UDT, which appears to be where you would determine the slave ID when using a gateway. Any information is helpful! Thanks Jeremy [/INST] Modbus TCP Client AOI supports up to 5 transactions. Based on your description, you need more than 100. It's possible to increase the number of transactions by changing the Transaction array size, but this is not something that I would recommend. Also all transactions are executed sequentially, so performance will be slow. Another option is to multiplex different data into the same transaction, but this will be even slower. If your TCP-RTU gateway supports multiple connections from the same IP address, then you maybe able to use more than one AOI pointing to the same gateway, but some devices will refuse more than one TCP connection from the same Client IP. If you setup Modbus Gateway as a client, then Modbus TCP server AOI will be processing one command at the time (slow), and you may still be looking at the 100 command limitation. My recommendation is to find an Ethernet/IP to Modbus RTU gateway instead, maybe use more than one. - Chaining Gateways sounds like a headache you don't need. Have you considered an EIP to RTU gateway like Prosoft offers? I'll bet they can handle 100 commands over multiple transactions. I have used Spectrum Gateways device for Modbus TCP and RTU on PLCs from PLC-5 through L81. They are dead simple to use but not as full featured in their command set. If it's just reading and writing registers they are worth a look. I have also used the Modbus AOI on a 5380 for 485 comms over a 5069-serial. But I don't use 100 commands so I don't know if that is possible. Aparian Gateway series B supports up to 100 commands. if you need more, then you can use an additional gateway. https://www.aparian.com/products/modbusrouterb Just for a quick requirements/sanity check, are all 100+ commands directed to a single controller or are you communicating with different addresses for each of the 12 nodes? Are you consolidating nearby addresses into single commands, or are you planning 1 address per command? I can only speak to Prosoft modules, but my first thought is that you could run out of memory on a single MVI56E if you really have over 100 reads with several addresses in each. The default configuration is for 600 read & write addresses each, though you can reconfigure for a max of 5000 total however you like. In my experience, though, I've always tried to have fewer reads grab larger blocks of addresses and then simply ignore the ones I don't need. I don't think I've ever had to deal with more than 20 commands on a single gateway. Chip I've always tried to have fewer reads grab larger blocks of addresses and then simply ignore the ones I don't need. This right here. n </s>
<s>[INST] Error installing 32.00.01-Studio5000-Web I have an error installing 32.00.01-Studio5000-Web. I used the managed downloader. Used 7zip to uncompress the multi part rar. Had IT at my company remote in and use open Setup.exe with admin privileges. Posted is the log file. Any help would be appreciated. I work 12hr nights at smith Wesson, so can not use the live chat feature. Thank you, Keil Common Install: Begin Studio 5000 Setup Common Install: Copyright © 2018 Rockwell Automation Technologies, Inc. All Rights Reserved. Common Install: Executing on: Sat, 20 Jul 2019 10:39:41 GMT Common Install: The current OS is: Name=Windows 10 Edition=Enterprise Bit=64 Major=10 Minor=0 ServicePack=0 IsServer=False Common Install: Setting the current working directory to [C:UserskmillerDesktop32.00.01-Studio5000-Web] Common Install: Begin parsing command line Common Install: End parsing command line Common Install: Can't found file Sequence.cfg. Common Install: [Info] Begin loading step: Checking if hanging reboot existed... Common Install: Time value of PrerequisiteInstall key not found... not waiting for a reboot. Common Install: DeleteRegistryItem: Begin: Class: [HKLM] Key: [SOFTWARERockwell SoftwareSetupCommonInstall] ValueName: [Install_Time_Studio 5000] Common Install: Failed to delete Registry vaule: Install_Time_Studio 5000. Exception message: No value exists with that name. Common Install: Time value of PrerequisiteInstall key not found... not waiting for a reboot. Common Install: DeleteRegistryItem: Begin: Class: [HKLM] Key: [SOFTWARERockwell SoftwareSetupCommonInstall] ValueName: [Uninstall_Time_Studio 5000] Common Install: Failed to delete Registry vaule: Uninstall_Time_Studio 5000. Exception message: No value exists with that name. Common Install: [Info] End loading step: Checking if hanging reboot existed... Common Install: [Info] Begin loading step: Checking if hanging reboot existed... Common Install: Time value of PrerequisiteInstall key not found... not waiting for a reboot. Common Install: DeleteRegistryItem: Begin: Class: [HKLM] Key: [SOFTWARERockwell SoftwareSetupCommonInstall] ValueName: [Install_Time_Studio 5000] Common Install: Failed to delete Registry vaule: Install_Time_Studio 5000. Exception message: No value exists with that name. Common Install: Time value of PrerequisiteInstall key not found... not waiting for a reboot. Common Install: DeleteRegistryItem: Begin: Class: [HKLM] Key: [SOFTWARERockwell SoftwareSetupCommonInstall] ValueName: [Uninstall_Time_Studio 5000] Common Install: Failed to delete Registry vaule: Uninstall_Time_Studio 5000. Exception message: No value exists with that name. Common Install: [Info] End loading step: Checking if hanging reboot existed... Common Install: [Info] Begin loading step: Silencing Windows Installer Common Install: [Info] End loading step: Silencing Windows Installer Common Install: [Info] Begin loading step: Parse configuration file. Common Install: Begin to parse C:UserskmillerDesktop32.00.01-Studio5000-WebConfigLogix_V32.xml Common Install: [Microsoft SQL Server Compact Edition v4.0.8482] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY True IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft SQL Server Compact Edition v4.0.8482 (x64)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY True PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft SQL Server 2012 Native Client v11.4.7001.0] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY True IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft SQL Server 2012 Native Client x64 v11.4.7001.0 (x64)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY True PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft .NET Framework v4.6.2] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft .NET Framework] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft Visual C++ 2017 Redistributable (x86) v14.15.26706.0] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft Visual C++ 2017 Redistributable (x64) v14.15.26706.0 (x64)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY True PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft Visual C++ 2013 Redistributable (x86) v12.0.21005.01] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft Visual C++ 2013 Redistributable (x64) v12.0.21005.01 (x64)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY True PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft Visual C++ 2012 Redistributable (x86) v11.0.61030] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft Visual C++ 2012 Redistributable (x64) v11.0.61030 (x64)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY True PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [InstallShield Script Engine v3.00.185] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft ODBC Driver 13.1 for SQL Server v13.1.811.168] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY True IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft ODBC Driver 13.1 for SQL Server x64 v13.1.811.168 (x64)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY True PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [OPC .NET API v2.01.10600] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [OPC Core Components v3.00.10600 (x64)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY True PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [FactoryTalk Diagnostics v6.11.00 (CPR 9 SR 11)] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Windows Firewall Configuration Utility v1.00.12.0003] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [CodeMeter Runtime Kit] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Updater IIS Installer v1.00.01] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Microsoft Visual Studio 2015 Shell (Isolated)] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Prerequisites] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False IS_LOADED_FROM_XML_CONFIG True Common Install: [FTSP IIS Installer v1.00.00] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_EXE True IS_LOADED_FROM_XML_CONFIG True Common Install: [FactoryTalk Services Platform v6.11.00] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED True SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [FactoryTalk Activation Manager v4.03.03] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED True SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [FactoryTalk Linx v6.11.00] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED True SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [FactoryTalk Alarms and Events v6.11.00] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED True SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer English] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE True PRODUCT_SELECTED True PRODUCT_INITIALLY_SELECTED True IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Portuguese PTB] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer French FRA] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Italian ITA] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer German DEU] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Spanish ESP] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Chinese CHS] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Japanese JPN] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Korean KOR] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED True HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION False IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Samples] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer v32.00] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE True PRODUCT_SELECTED True PRODUCT_INITIALLY_SELECTED True IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False IS_LOADED_FROM_XML_CONFIG True Common Install: [MRSCmn Help Package] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Release Notes] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Uninstaller] properties: SHOW_MAJOR_IN_VERSION False SHOW_MINOR_IN_VERSION False SHOW_BUILD_IN_VERSION False SHOW_UPDATE_IN_VERSION False SHOW_EXTRA_IN_VERSION False PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL True IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Logix Designer Motion Database v33.0.4998] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT False REG_VISIBLE_IF_INSTALLED False IS_CRITICAL False IS_SHOWN_IN_INSTALLATION_SUMMARY True IS_SHARED False SHOW_NAME_IN_VERSION True IS_MSI True SKIP_UNINSTALL_BEFORE_UPGRADE False IS_CONFIGURABLE True IS_LOADED_FROM_XML_CONFIG True Common Install: [Studio 5000 Launcher v3.7.293] properties: SHOW_MAJOR_IN_VERSION True SHOW_MINOR_IN_VERSION True SHOW_BUILD_IN_VERSION True SHOW_UPDATE_IN_VERSION True SHOW_EXTRA_IN_VERSION True PLATFORM_64BITONLY False PLATFORM_32BITONLY False IS_EXPLICITLY_REQUIRED False CACHED_SELECTED_VALUE False PRODUCT_SELECTED False PRODUCT_INITIALLY_SELECTED False IS_PROTECTED False HAS_MULTIPLE_VERSION_SUPPORT True REG_VISIBLE_IF_INSTALLED& [/INST] If you used the managed downloaded, you should end up with 4 files after the downloader finishes - an EXE and 3 RAR files. DO NOT unpack them with a 3rd party package like 7ZIP. Instead, simply run the EXE. It will unpack the things it wants from the 3 RAR files on its own. TJ @ Systems Interface said: If you used the managed downloaded, you should end up with 4 files after the downloader finishes - an EXE and 3 RAR files. DO NOT unpack them with a 3rd party package like 7ZIP. Instead, simply run the EXE. It will unpack the things it wants from the 3 RAR files on its own. View original This worked. Thank you. n </s>
<s>[INST] POWER FLEX 755 X 08 NOT FUNCTIONING, X 05 NOT FUNCTIONING Summary: Drive doesn't start without clearing this faultENVIRONMENT:<o:p></o:p> CAT NO: 20G1A NC 140 AA0NNNNN (Series A) S/N: 27609796 FRN: 9.001 MFD: 2013/07/12<o:p></o:p> CUSTOMER: Ball Beverage Packaging India Pvt. Ltd.<o:p></o:p> QUESTION: As per telephonic discussion with customer he told me that, <o:p></o:p> Since last one year they are having more issues in control card, catalog no. SK-R1-BP1, used in PF 755 series drives. Which are rated at more than 40 HP. Once in a while they are having fault ‘ X 08 not functioning’ or ‘X 05 not functioning’ and the drive does not run unless and until they replace this control card. Surprisingly they are not using any of these ports.<o:p></o:p> - In last one year they have replaced atleast 10 cards.<o:p></o:p> Request you to look into the root cause behind the failure and suggest us how we can reduce the failure rate. <o:p></o:p> please find the attachments of control card and fault message.<o:p></o:p> [/INST] Why is the customer replacing the backplane board? Why not replace the main control board? That seems like a much more likely suspect than the backplane board that has nothing connected to port 8. Note that port 8 and port 5 are on two different backplanes. Has this customer been replacing both backplanes? What option cards ARE installed in this drive? Anything at all? Encoder card? IO card? Safe-Torque-Off or Safe-Speed-Off? Is it possible to get a DNO file from this drive (using Drive Executive) or whatever the file format is for CCW? If you can get that file and upload it here, we might be able to help more. https://rockwellautomation.custhelp.com/app/answers/detail/a_id/469632/page/1 The technote above goes through the troubleshooting / replacement for the problem you describe. You're at the step where the main control board should be replaced. Thanks for your quick reply. They are not using any option cards in option slots, they are providing commands to drive from embedded ethernet port. I asked them to provide parameter files, if I'll get one I'll definitely upload it here. Yes, customer had replaced both of the backplane in past and recently they also replaced the main board. currently, their system is working fine but they are asking about the causes of these errors. what could be reason of these faults ? Since no slots were ever being used, I think the original problem lay with the main control board being defective. Unless you have the end user send the board back to Rockwell for Root Cause Failure Analysis (and this is NOT a free service), knowing the specific reason will not be known. At this point, if the problem is solved by the customer changing the backplane boards and the main control board, you can tell them the main board was defective. I lean more towards the main board because you said the conflict error came up for slot 8 and slot 5. Each of those is on a different backplane board. For both backplanes to be defective in the same drive when they're not even being used seems highly improbable. The common factor for both of those is the main control board. Thanks a lot mate. Is your drive in a corrosive atmosphere....close to corrosive atmosphere? n </s>
<s>[INST] Cold Junction Sensor for a 1756-IT6I swing arm - what is it? Summary: What kind of cold junction sensor does the 1756-IT6I card use?I'm missing the cold junction sensor for a 1756-IT6I card I have on a test bench (using a 1756-TBNH/A terminal block right on the card). Is it possible to cobble up my own? Is it just a small thermocouple to sense the temperature at the card's terminal block? (Our local A.B. dealer doesn't have one in stock and I'd like to get my testing done without having to wait on having one delivered from wherever). Nick [/INST] Cold Junction Compensator sensors are typicall Resistive Temperature Device (RTD) sensors, since those have a pretty good absolute accuracy at the ambient temperatures the module is going to encounter. My guess is that it's a 100 ohm platinum RTD. Without the CJC, a typical Type J Thermocouple will read about 86 degrees F lower than actual temperature. Try a 100 ohm platinum RTD and see if you get a reasonable ambient temperature. RA Technical Support could probably figure this out; I haven't found this detail in the Knowledgebase. Thanks Kakkerlak, I'll give that a try. Nick I tried a 100 ohm platinum RTD and unfortunately it didn't work. End of a week... I ordered the part from our A.B. dealer. Hopefully, it won't take too long to get here. Thanks, Nick Part arrived from A.B. dealer and FYI, the cold junction sensor is just a thermistor. No spec's on it, so can't say what the thermistor spec's are. Nick Thanks for feeding back that info. When you get the CJC, measure it and let us know what you find ! n </s>
<s>[INST] Anyone configure 1734-IB8S with Guardlogix via 1734-PDN ??? I know this is not supported by AB, but there is a technote that says technically it is possible. I'm assuming I have to use a Generic Devicenet Safety Module configuration and manually set the Input / Ouput Assembly Instances and size in bytes. Anyone done this? Help. :smileysad: [/INST] I got an email from Bob Law (Dr. Devicenet) whom gave a document which describes step by step how to configure the 1734-IB8s and OB8S via PDN to Guardlogix. Very nice. FYI. Can you please share the document. please share.. Mr. Singh, I replied to your private message with Bob Law's email address. I dont have permission to post it pubilicly, but you can get it from him. Our customer has this running perfectly for quite some time now. n </s>
<s>[INST] Ghosts of ActiveX At 2 customers an ActiveX controls called ProgressBar died last week. Our graphics have been using a bunch of ActiveX controls for years. Many going back to RSView32 and still work in FTView. I know ActiveX poses a major security concern. Microsoft has been trying to kill it for years and tightening the restrictions on it. I know other programs have suddenly died when Microsoft did security update killing an ActiveX extension. A friend of mine had to convert a bunch of ActiveX modules to more standard DLLs to keep his stuff working. Has anyone else experienced the sudden death of an ActiveX control? [/INST] nan n </s>
<s>[INST] Logix V13 I am attempting to add a module to an operating Control Logix system. When I goto the module configuration and right click the New Module selection is greyed out. I was able to add a module in a simular fassion using Logix V15. Does anybody know if there is a problem doing this using V13 ?? [/INST] Maybe a silly question.... are there available free slots to add the new module in the chassis configuration ? :smileytongue: Otherwise, may you post the .ACD file (insert it in a .zip file) ? - fuzzy logic The option to add a module to the local or a remote chassis at runtime was not added until firmware revision 15. Thanks, I hought that may be the case.I'll have to Flash it to 15 when we shutdown next. Ahhh.... you're trying it in online / run mode ... :smileysurprised: always I read too quickly... :smileytongue: MikeThom answer is correct, though... Aid 45086 Apologize for confusion.... - fuzzy logic n </s>
<s>[INST] Controllogix and Panelview Comm Is there a way for a 1756-L81E connected to a Panelview plus 7 performance to recognize a loss of communication with the Panelview. And vice versa, the Panelview recognize the loss of comm from the processor? I've set up a tag that sends the seconds of the Panelview to the PLC and evaluates if there is a change but that is a slow way to know there is a loss of comms. Is there something built into the system that can recognize a comm issue? [/INST] There is a couple of ways {[Shortcut]@IsPresent} int the PV. Or a GSV in logic. Is there some documentation on the use of those instructions? And to clarify this is via Ethernet and my understanding is that GSV doesn't work in that case. Here is a technote that shows how to use GSV to monitor status of anything in the PLC's I/O tree: QA4421 (Techconnect Reqd) Regards, RM The Panelview Plus 7 isn't added to the I/O tree of the ControlLogix L81E so that wouldn't work. If you want to try something completely different, here is a technote that uses ActiveX controls to play tag between the PLC and PVP: QA19466 (Techconnect required) You seem to be concerned about the speed of detecting the comm loss, though, and this method appears to be limited to a two second rate. Regards, RM You could potentially use the systemBlinkFast or systemBlinkSlow tags in the HMI to trigger a value change in a tag on the PLC, similar to your seconds counting. BlinkFast is 100ms and BlinkSlow is 500ms. Regards, RM Hi @Stephen Hancock were you able to find a solution? I also found QA50090 with an example that might be useful. The limit here is basically the short time you would like the comm loss to be detected. Is there a specific reason for trying to reduce this time? Please don't forget to LIKE and highlight the decisive answer: REPLY > Make Best Answer n </s>
<s>[INST] Getting supply authority data into FactoryTalk EnergyMetrix Has anyone tried to get the meter logged data from a supply authority into FactoryTalk EnergyMetrix. The supply authority makes the data available to the account holder online. I would like to automate the process of collecting the logged data and entering it into FactoryTalk EnergyMetrix's database so it can be used alongside the data collected locally. Are there any established protocol's or drivers? John [/INST] Hi John, unfortunately I'm not an expert on the subject, but would like to help in some way. Reading the User Manual I can understand that some devices from Rockwell Automation can be directly integrated to the FactoryTalk EnergyMetrix, while third-party meters​ and other data sources can leverage the OPC communication option to consolidate energy-related information into the system. FactoryTalk EnergyMetrix OPC enables Manager to collect data from third-party energy data sources through an OPC server that you provide. If not already done, I suggest to start from that document; here is the link to download it: USER MANUAL Another source of information that could be useful is the Quick Start guide for the Energy Management Accelerator Toolkit. Unfortunately the Toolkit has been retired, but the manual can give you some hints about meters communication and settings. Hope this helps. fuzzy logic Please don't forget to use the LIKE button and highlight the decisive answer : REPLY > Make Best Answer n </s>
<s>[INST] powerflex variable frequency drive 753 EDIT: moved to Drives and Motion community -FL Hi, I was using a powerflex 753 cat no -20F11 N D 022 JA0NNNNN and recently it burned . On investigation I found out that this frequency drive is designed for 480 v 60 hz input whereas power input provided was 400 v 50 hz . Has it burned due to wrong input as I later found out that for 400 v 50 hz cat no should be -20F11 N C 022 JA0NNNNN. Please clarify. [/INST] Hello Mohan, The VSD has the capability of swapping between 400V and 480V using parameter 305. Parameter 305 is set to either 400V or 480V depending on the Catalog number of the VSD. This lead me to believe that the voltage range of the VSD is capable of 400V or 480V. This is explained in QA46486 and QA16097 I would suggest send the VSD to the repair shop, they will provide a detailed repair report indicating what components failed. Hope this helps. Agreed. And I can confirm about: This lead me to believe that the voltage range of the VSD is capable of 400V or 480V. See the following picture, taken from PowerFlex 750-Series AC Drives Technical Data, publication 750-TD001: Please don't forget to LIKE and highlight the decisive answer: REPLY > Make Best Answer n </s>
<s>[INST] FTView Studio legacy tag patch roll-up [/INST] There is no question here.... n </s>
<s>[INST] Slow datalogging to mySQL server Summary: RSVIEW32 DataloggingI am datalogging about 1,000 tags at 1 min intervals. I switched to mySQL and partitioned the table into 2-day long partitions. I wrote a web application in Javascript, so anyone in the plant can select tags by name or number (autocompletes, e.g. enter 036 and all tags with 036, e.g. LIC-036 and their descriptions show up). It allows cross-plotting and zoom -- I used DyGraphs for plotting. Once I did the partitioning, the plotting application, runs relatively quickly. It can even calculate derivatives, totals, and averages with one click. The only problem it's giving me, after a year of datalogging, whenever I start RSVIEW32 or exit, it takes it FIFTEEN MINUTES. Why? This is a small number of tags to be logging, it seems like the software must scan the tables at start-up or something? How can I avoid this problem? The mySQL server resides on a different computer than RSVIEW32. I am running version 7.40. Is there any way I can look at what commands RSVIEW32 is issuing to the server and somehow optimize them? [/INST] Everything about mySQL is slower. Not related to RS I did some comparisons with MS's SQL Server about 1.5 years ago. Every thing in mySQL was 10 to over 100 times slower. First queries were especially slow so what you are reporting does not seem odd to me. Have you tried PostgreSQL. It was faster than mySQL especially for first queries but still not as fast as MS's SQL Server. The bottom line is you get what you pay for. n </s>
<s>[INST] Tag browsing What we have is a L64 processor that is deep into the yellow of the used memory. The system has already 3 processors 2 for motion and the third for the logic and recipe information. The the recipe tags are 6 UDT's that contain 50 potential Models for a total of 300 Recipes. These 6 UDT's use about 10 M of data. We have come up with two solutions and would like some feed back:The current batch look through UDT 1 for a match then UDT 2 then 3 so on so on till it finds a match. It then copies the Data to a tracking area that follows the part though the system. This way each we can have differnt models with different options through out the line. Solution 1:Can I have the batch search a fourth Processor tags as if it were it's own that would contain the Model data tags directly over the back plain and copy the matching Models information to its Tracking area. Solution 2:Create a Produced tag in the original Processor that asks the Data processor for model information. Then the Data Processor would search the 6 UDT areas for a match. When one is found copy the Model Data to a produced tag along with a complete hand-off bit. Then the Original Processor would consume this data after seeing the complete bit. Then copy this information to the necessary Tracking area. After completing the copy clear the hand-off tag. There’s probably a bit more to the steps of solution 2. I’m confident we could get it to work the main question is about solution 1. Is that possible to brows the tags of a different processor as if they where you own tags. [/INST] capple, I think solution 2 is the only. It isn't possible to browse directly tags that resides in another controller using RS5000... :smileysad: - fuzzy logic I though so but I knew I would get a concrete answer here Thanks The Produced/Consumed tags did not work. The size of 1 Model_Data is 20K. So now I am using a Message (CIP Data table Read) now my dilemma is to change the Source Element during Run Time. I need this to be an Indirect Tag but it did not accept one. So far the work around I found was to make a pointer array of 300 Strings then call the pointer that contains the required String and copy it to the Mesage_Control.RemoteElement. Now the question is how do I eliminate the array of 300 strings and just make some kind of move instruction to move a tag like:S001.Model_Data[Indirect Number] <<<< UPDATE>>>>I came up with a solution and thought I would share Using the DTOS and INSERT Instructions.I haven’t cleaned this up to a final project but here is what I tested. // Update Line A Model Dataif S100.Batch.Data.Order[1].Model_Number[0]=S001.Model_Data[1].Model_Number then Batch_Search.Control[1].Search_Required:=0; Line_A_Search:=0;else cop(S100.Batch.Data.Order[1].Model_Number[0],Batch_Search.Model_Name[1],1); Batch_Search.Control[1].Search_Required:=1; Line_A_Search:=1;end_if; // Prepare MSG Remote Data Location If Line_A_Search then if Model_Location.S001>0 and Model_Location.S001<=50 then Dtos(Model_Location.S001,SourceB[1]); Insert(SourceA[1],SourceB[1],17,MSG_Control_1.RemoteElement); //SourceA = S001.Model_Data[], SourceB = 1-50 end_if; if Model_Location.S002>0 and Model_Location.S002<=50 then Dtos(Model_Location.S002,SourceB[2]); Insert(SourceA[2],SourceB[2],17,MSG_Control_1.RemoteElement); //SourceA = S002.Model_Data[], SourceB = 1-50 end_if; if Model_Location.S003>0 and Model_Location.S003<=50 then Dtos(Model_Location.S003,SourceB[3]); Insert(SourceA[3],SourceB[3],17,MSG_Control_1.RemoteElement); //SourceA = S003.Model_Data[], SourceB = 1-50 end_if; if Model_Location.S004>0 and Model_Location.S004<=50 then Dtos(Model_Location.S004,SourceB[4]); Insert(SourceA[4],SourceB[4],17,MSG_Control_1.RemoteElement); //SourceA = S004.Model_Data[], SourceB = 1-50 end_if; if Model_Location.S005>0 and Model_Location.S005<=50 then Dtos(Model_Location.S005,SourceB[5]); Insert(SourceA[5],SourceB[5],17,MSG_Control_1.RemoteElement); //SourceA = S005.Model_Data[], SourceB = 1-50 end_if; if Model_Location.S006>0 and Model_Location.S006<=50 then Dtos(Model_Location.S006,SourceB[6]); Insert(SourceA[6],SourceB[6],17,MSG_Control_1.RemoteElement); //SourceA = S006.Model_Data[], SourceB = 1-50 end_if; else cop(SourceB[0],SourceB[1],6);end_if; Then I use a MSG to get the Value of the desired Model_Data n </s>
<s>[INST] RSSQL Transacion Manager: Error 33078 Hello everyone, this error RSSQL Transacion Manager: thread closed the transaction with the error 33078. is appearing in my Transaction Manager, the error is very recurrent and is causing all transactions to fail, can someone help me with this error? Greetings. [/INST] Welcome to Engage, Luis Armando! To get the most out of the Community, it would be better to complete your request with more details, like software version and OS version. Have you noticed if this happened as a result of some operating system update? fuzzy logic Please don't forget to LIKE and highlight the decisive answer: REPLY > Make Best Answer Sure, my version of Transaction Manager is 10.20.00, SQL Server 2014 with Windows Server 2012 R2 OS. Hi Luis, Error 33078 is transaction timeout, you may need to investigate the configuration and how you are triggering transactions, things like how fast the transactions are triggering, how many are triggering, what if anything is happening on database side, whatever query you have running in your database is taking too long, if the current timeout value is reasonable. You should investigate your database to improve it's performance. Refer the knowledgebase id BF19440 will help to troubleshoot problems with FTTM Data Collection. Typically increasing the timeout value will help but you may have to enable debug logging to trace through the transaction to see where it's spending it's time. Guidelines for Setting Various Timeout Values, refer KB ID: IN14976 Please consider that a TechConnect contract is required to access the above technote. Hope this helps. n </s>
<s>[INST] Emailing a Tank Value Every 24 hours Summary: Would like to set up an automated email message to give me a tank value every morning I have a number of tanks and have email working out of the controllers they are attached to, what im confused on is how to insert the REAL value into the string to be emailed out. [/INST] What hardware are you using? The more detail you provide, the better the answer you'll get. I Use Excel to run at Various Intervals throughout the Day to get Data out of Machine PLC's and create a Report, all Automatically. Some of my Reports are every 15 min, Some are every 2 Hours, Some are at the end of each shift, and 2 are Every morning at 8am. The 2 that run at 8am are 2 Machine I gather Data from in Mexico. I have also done similar things with Water and Waste Water Plants in My Past. I Like having all the Code in One Place instead of all the Different Controllers. Must have RSLinx OEM or Up, and Microsoft Office. I have 5/04's in my Plant Tied thru a Controllogix Gateway into our Company Network. Not done the email thing out of controllers but you can program Excel to gather all the Tank's Levels and send out a Single Email Report from Excel. Since the excel code goes out to the Specific PLC, you already know which tank you are getting the value for. All you are getting from the Tank is the Live Level value. You can take that value embed it into a text string in the VBA code and create a report, or even just append the value to a simple CSV file, or populate a cell. You cna even just have a file that you open up and have a nice report and when you click a button it gethers the values in the report and then print yourself. alot you can do with it. Of course a SCADA Package with Historian is the Best way, RSView, Wonderware, Intellution, Etc. Working on building up a Wonderware system at my plant. Already doing exacly this. See the attached pdf file for the code. I selected email me when others post a new comment if you want to respond. SLC, Micrologix and PLC5 all have functions to convert Integer to string formats. The AIC Integer to string. But for real you can extract the decimal from a real and then convert them and append to the string with a . in between. n </s>
<s>[INST] 1756-L73 In Rslogix 20.4 & 1756-L81ES Produce / Consume Hi, We're Control System Have 1756-L73 ( Central ) And Several 1756-L71 & 1756-L71S , Using Produce / Consume Method To Make Data Exchange And Program by Rslogix 20.4 , Recently Add 3 Machine That Build by 1756-L81ES Program by Studio 5000 V32 , I Has Been Try To Config Network Communication 1567-L73 On New Modules But New CPU And Network 1756-L81ES Did'nt Show On List , How Can I Make Data Exchange By Produce / Consume Or Other Way To Make It . Thank you. ======================= Resolved , My Program Notebook Have 2 With Different Vision Software A. Rslogix 20.4 (org) B. Studio 5000 V32 (new) , So I Try Install Studio 5000 V32 To Org. Notebook , Finally Config 1756-L73 Network Communication On New Modules Is Done . [/INST] Welcome to Engage! Thank you for posting what you found to get your problem solved. Just for future reference, I'm posting here a couple of links to useful technotes on the subject: QA57675 - Safety Tags produced by a GuardLogix 5580 controller consumed by older GuardLogix 5570 controllers QA52684 - Produce and Consume tags between 5580 and older RSLogix 5000 based controllers Please consider that a TechConnect contract is required to access the above technotes. fuzzy logic Please don't forget to LIKE and highlight the decisive answer: REPLY > Make Best Answer n </s>
<s>[INST] SLC Presentation ? Dear All,if any one have presentation on SLC troubleshooting & Maintenance, I need it badly.any one having relevant data?will be very thankful to you for this [/INST] Try to take a look (unless already done) to the User Manual and the Reference Manual...both contain Troubleshooting chapter that is useful for that.... Hope this helps… - fuzzy logic n </s>
<s>[INST] PowerFlex 755 Dual Encoder AqB Feedback. Summary: PowerFlex 755 CIP Motion With Dual Encoder AqB Feedback. Manuals are contradicting themselves.Hello all, Can you have a Universal Feedback Card in a PowerFlex 755 Drive and use Dual AqB Feedback on Both Channels with two A B Z encoders? I'm working on a project which involves dual encoder feedback and CIP motion (I've listed the hardware and software which I'm using at the bottom of the post). I've found that there is some contradictory information in the PowerFlex 750-Series AC Drives Programming Manual (750-pm001) and the PowerFlex 750-Series AC Drives Technical Data (750-td001). The PowerFlex 750-Series AC Drives Programming Manual Appendix F (Page 522) shows that in Table 30 Universal Feedback Type and Connections that Digital AqB can be used. The wiring for the terminals are shown in the table. The PowerFlex 750-Series AC Drives Technical Data Encoder Combinations Compatible with Universal Feedback Boards(Page 153) shows that two incremental A B Z encoders can't be used. I've attached Images of both tables to this post. (One is the image attached to the post, the other is the file. There seems no way for linking multiple images). Can anyone provide some more detail on AqB? Which encoders use this feedback type other than A B Z? Hardware: Guard Logix 5580 Controller (1756-L82ES). PowerFlex 755 AC Drive with Embedded Ethernet/IP & Safe Speed Card (20G11NB2P2JA0NNNNN). Software: Studio 5000 Logix Designer Version 31. RSLinx Classic Version 3.51.00 or Later. Cheers, Spencer P. [/INST] I am completely lost not being able to find what fault code 10138 is all about on the fault code manual for powerflex 755. Can someone guide me on this? Francis, You might want to post your own topic on the subject rather then in the middle of this one. That being said, I've found this that relates to code 10138. That was in the programming manual. I found it by doing a search (Cntrl+F) and looked for the code. I Hope this helps you out. After more research on the topic. I've come understand the the AqB is a protocol which is used in many different kinds of encoders, not just the ABZ encoder. So a combination of AqB is possible, but just not two ABZ encoders can be used together. Edit: If two ABZ encoders are required the 20-750-ENC2 card takes two incremental encoder inputs but occupies just one slot . Or two encoder cards can be used instead. Spencer, the 20-750-ENC2 card takes two incremental encoder inputs but occupies just one slot. Thanks TJ, Sorry I misspoke when I had wrote must use two encoder cards I've edited the above comment to reflect your advice as well. Cheers, SP. n </s>
<s>[INST] Allen Bradley tutorial training Hello Experts, Iam newbie in Allen Bradley software. Kindly post us with Allen Bradley tutorial training for: RSLogix 500 V20 RSLogix 5000 V20 FactoryTalk View Machine Edition V8 FactoryTalk View Studio ME V8 RSLinx Classic RSLinx enterprise Best regards....... [/INST] The Rockwell Literature Library has many user, programming, and reference manuals. http://literature.rockwellautomation.com/idc/groups/public/documents/webassets/browse_category.hcst If you have an OEM Toolkit license, then there is some pretty good training software that is part of the toolkit (RSTrainer). Your Rockwell Distributor may offer training (some free, some paid). You can also hire a systems integrator to help you with programming and training. Remember that this is a user's forum - Rockwell users helping other users. It is not formally monitored by Rockwell employees, though some do visit here to help. Hello, 1-What is OEM Toolkit license? 2-How to obtain toolkit for RSTrainer through internet? Best regards........ The toolkit license grants you one year's access to essentially ALL of Rockwell's software (including all that you listed in your post). It grants you access to all versions (current and past). This is a one-year license and you are expected to renew it each year. RSTrainer is one software package available with the toolkit license. When you purchase the license, Rockwell sends you a USB hard drive loaded with that year's releases. However, as upgrades and new versions become available throughout the year, you can download them from the Rockwell software web site. You need the license in order to access the site. The basic brochure is here: http://literature.rockwellautomation.com/idc/groups/literature/documents/ap/oem-ap055_-en-p.pdf Search the literature library for more: http://search.rockwellautomation.com/search?q=oem%20toolkit&site=literature&sort=date%3AD%3AL%3Ad1&btnG=Submit+Search&entqr=0&client=literature&access=p&oe=UTF-8&ie=UTF-8&ud=1&proxystylesheet=literature&output=xml_no_dtd&spell=1&getfields=*&filter=0&country=&lang=&hl=en You should also contact your local Rockwell distributor for more information and for pricing. Thank you very much for your reply. Hello, Kindly check the following link: http://literature.rockwellautomation.com/idc/groups/public/documents/webassets/browse_category.hcst I noticed that all the documentations doesn't appear together as before. Did Allen Bradley change the link? Best regards....... Is there any Laboratory practice to learn how to work in Micrologix 1100 RSLogix500 with an analog input sensor and the scale programming instruction ? n </s>
<s>[INST] FactoryTalk SE with Remote Desktop We have installed FactoryTalk SE (I think ME is also installed for that matter) on a workgroup server and when we try to open FactoryTalk Linx Browser, we have this error message: Read-Only. Unbale to change browser due to nobody log on. We rare connecting through Microsoft Remote Desktop. The funny part is if we try the same thing but, log on to the server using VMWare console, we do not have that error message. What I can understand is that while we logon interactively (the VMWare Console), FactoryTalk is acting fine but if we log on using Terminal Service we cannot use the software. How can we manage to use the software while using Terminal Server (Remote Desktop)? Version info for FactoryTalk Administration Console Release Number: 6.20.00 (CPR 9 SR 12) Service Release: 00 Build Number: 548 We are running the software on Windows Server 2019 Thank you, Mathieu [/INST] If I understand right, please open FactoryTalk admin console application in the PC first, keep it opened, then you can use windows remote connection and open other windows successfully. Actually this is the security default configuration by FactoryTalk, and you can use above method or change the security configuration in FactoryTalk Admin Console. Thank you for confirming the behavior. I did the adjustment using the policy and it seem to work as intended. Revised from previous response. After thinking about this and consulting people much smarter than me, I realized I ran into something similar when trying to remote desktop into the Windows core on a CompactLogix 5480. I believe this is controlled by a System policy -> security Policy setting that identifies terminal server clients. The default is terminal client so change it to server computer and you should be able to access the admin console. n </s>